ADDITIONAL FEATURES (continued)
Low Battery Indicator:
Low Battery indication is shown for the home unit itself and all of the remote sensors (up to 3). When the low battery indicator is displayed, replace the batteries and follow the setup procedure as shown in this instruction manual.
SPECIFICATIONS: | |
Range of temperature measurement: | |
Indoor unit | : 32º F to 122º F (0º C to 50º C), 20% - 99% RH |
Remote sensor | : |
Transmission | : up to 100 feet (30 M) in an open area |
Resolution | : 0.1 degree for temperature, 1% for RH |
Moon phase | : 8 resolutions |
Battery | : 2- “AA” for the main unit, 2 “AAA” for each remote sensor. |
|
| Alkaline batteries are recommended. |
| ||||
BUTTON FUNCTIONS: |
| ||||||
|
|
|
|
| |||
| BUTTON |
| PRESS BUTTON ONCE |
| PRESS & HOLD FOR 3 SECONDS | ||
BUTTONS | SET |
| Start or stop radio controlled |
| Enter clock & calender set mode | ||
|
| time signal search |
| ||||
|
|
|
|
| |||
|
|
|
|
|
| ||
| ALARM | Read alarm time for 5 seconds |
| Enter alarm set mode | |||
FRONT | MIN/MAX |
| Read Maximum / Minimum record |
| N/A (no function) | ||
|
|
|
| for 5 seconds |
|
| |
|
|
|
|
|
|
| |
| CHANNEL | Select channel 1 to 3 for viewing |
| Delete current channel reading | |||
|
|
|
|
|
|
|
|
BUTTONS | + |
| Advance in settings by one step |
| Fast forward through settings | ||
_ |
| Turn the alarm on or off |
|
| |||
| Move back in settings by one step |
| Fast backwards through settings | ||||
| Switch thermometer reading |
| |||||
BACK |
|
|
|
| between C and F |
| Time zone selection (P/M/C/E) |
|
|
|
|
|
| ||
SNOOZE / LIGHT |
| Activates snooze / backlight (3 sec.) |
| N/A (no function) | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
00786 Wireless Indoor/outdoor Weather Station
H | I | J |
TX | C/F |
|
Home Receiver | Remote | Bracket | |
Sensor | Stand | ||
|
STEP ONE: SETTING UP THE WIRELESS THERMOMETER
Home Receiver Set Up:
For the initial installation, always insert batteries in the home unit first, and then the remote sensor. Remove the battery cover on the back and install 2 “AA” batteries (not included) according to the polarity indicated. Replace the battery cover.
Remote Sensor Set Up:
Remove the bracket stand and remove the 4 screws with a small phillips head screwdriver. Insert 2 “AAA” alkaline or lithium batteries (not included) according to the polarity indicated. Set channel 1 for the first remote sensor. To enable the weather forcastfeature, you must set to Ch 1 if only one sensor is in use. One sensor is included with the base unit. Additional sensors may be purchased seperately. Set channel 2 if using a second sensor, or channel 3 if using a third sensor. To purchase additional sensors call
•To verify transmission of a signal press the “TX” button inside the battery compartment of the remote sensor. The red LED on the front of the remote sensor will flash when it successfully transmits a signal. Temperature and humidity of the remote sensor will be updated and displayed on the remote sensor.
•Select Celsius or Fahrenheit by pressing the “C/F” button inside the battery compartment.
•Replace the cover and tighten the 4 phillips head screws.
4
STEP TWO: SETTING THE ATOMIC CLOCK
About The Atomic Clock:
The National Institute of Standards and Technology (NIST) in Fort Collins, Colorado broadcasts the time signal (WWVB at 60kHz AM radio signal) with an accuracy of one second per every 3,000 years. The signal covers a distance of up to 2,000 miles from the source.
Selecting the ideal location:
Like a typical AM radio, the Atomic Clock will not receive the WWVB signal in places surrounded by heavy concrete or metal panels. For best reception, please install the home reciever near a window. The time signal reception is also greatly affected by electrical or electronic interference. If the home receiver location you selected does not work, change to a location in another part of the room or building.
Radio Controlled Time Reception Set Up:
The clock attempts to synchronize with the Atomic time signal AUTOMATICALLY right after the first sensor is registered. The unit will start synchronizing the clock after registering the remote sensor thermometer reading. An antenna icon appears in the upper right hand of the time section. The clock will not respond to any manual settings while attempting to receive the Radio Control Time Signal. This reception cycle lasts from 2 to 5 minutes. The antenna icon remains fixed after the clock is synchronized.
Entering The Time Zone:
After the unit successfully synchronizes withthe atomic time signal, the time zone must be entered.
•Press & hold “C/F ZONE” button on the back of the home reciever for 3 seconds, press “C/F ZONE” button to select P/M/C/E time zones. The letters appear in the area where the seconds are shown in the time display. When you select thecorrect time zone, press the “SET” button to confirm your choice and exit the selection mode.
P = Pacific Standard Time | C = Central Standard Time |
M = Mountain Standard Time | E = Eastern Standard Time |
The clock will not respond to any manual settings while attempting to receive the Radio Control Time Signal. Press the “SET” button to turn the reception off and to enable manual settings.
Daylight Saving Time (DST) Feature :
The DST feature is enabled when the batteries are installed. The DST icon appears as a flashing “D.” For areas not using DST in summer, select DST off mode as described under Step Three: Manually Adjusting Clock & Calendar Setting.
1
STEP THREE: MANUALLY SETTING THE CLOCK & CALENDAR
Press and hold the “SET” button for 3 seconds:
•The setting sequence is:
Year > Month > Date > Hr > Min > 12/24 hr > DST on/off > Weather Offset > EXIT Settings
•Press the “+” or
•The corresponding digits will be flashing during the setting procedure.
•After completing the setting sequences pressing the “SET” button will return the display to the standard view.
ADDITIONAL FEATURES
Setting the Alarm:
Press and hold the “ALARM” button for 3 seconds.
•The display will show the alarm set time and the letters “AL” appear to the right of the minute digits. The hour digits will be flashing.
•Press the “+” or
•The minute digits will be flashing. Press the “+” or
•Press the “ALARM” button again to exit the setting procedure.
To stop the alarm, press any button when the alarm sounds. This will automatically reset the alarm to sound agian the next day at the same time. To turn off the alarm completely, press the “+” button on the back of the case. To turn the alarm back on for use, press the “+” again.
Snooze / Light:
Press the “snooze/Light” button to activate the 8 minute snooze alarm. Each press will also activate the green backlight which will remain illuminated for 3 seconds before turning itself off to conserve the batteries.
MIN / MAX Memory:
Press the “MIN/MAX” button to view the maximum indoor and outdoor temperature and indoor humidity values for 5 seconds. Press again to view the minimum values. The min/max memory will automatically clear every day at midnight.
Temperature Trend:
Small arrow icons displayed in boxes will indicate: Rising, Steady, Falling. Refresh rate for the outdoor temperature trend is once every hour.
Moon Phase:
Moon Phase is shown by the scrolling of the moon icon from left to right. The icon will stop at the existing moon phase for 5 seconds, and then resume scrolling.
2 | 3 |