Page 5 of 5
5.If the LED indicators respond as described, proceed to Step 6; otherwise, refer to the following to isolate the problem:
STATUS is red — The RLXIOR module has failed
NET LOS/BER is red — A DS1 signal is not being received from the network.
NET LOS/BER is yellow — The error rate of the DS1 network signal exceeds the threshold value (default value is
LINE LOS/BER is red — A DS1 signal is not being received from the line.
LINE LOS/BER is yellow — The error rate of the DS1 line signal exceeds the threshold value (default value is
6.Press the LMPTST switch on the APU to verify that all the LEDs on the front panel of the RLXIOR light yellow. This indicates that the LEDs are functional. If all LEDs do not light yellow, the module is defective; replace the module, then repeat Steps 1 through 6.
Note: The MPU must be installed in the chassis for Step 6 to work.
7. Repeat this entire procedure for each RLXIOR module.
Stop! You have completed this procedure.