ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-525

Page 6 of 6

INITIAL START-UP TEST AND

STAND ALONE OPERATION

Following insertion into the mounting shelf, the STATUS LED will initially turn red to indicate the start of self-test diagnostics. While self-test diagnostics are in progress, all LEDs will turn yellow and then remain on until self-test diagnostics are completed.

Following the successful completion of self-test diagnostics, the front panel LEDs will appear as follows:

STATUS - Green to indicate that self-test diagnostics were successfully completed.

LPBK - Off

NET/LOS - Red to indicate that the network DS1 signal is not being received by the RLX.

LINE/LOS - Red to indicate that the line DS1 signal is not being received by the RLX.

R

L

X

STAT

LPBK

ENBL

LOS

NET BER

LINE LOSW BER

I- V -

I+ V+

RESET

A2 RLX

R

L

X

+

STAT

LPBK

LOS

NET BER

LINE LOS

BER

I- V -

I+ V+

Version B RLX

7392-B

Figure 525-5. RLX Initial Start-Up Test

2-86