ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-539

Page 1 of 1

ACO (ALARM CUT-OFF) COMMAND

Summary: This procedure provides instructions for silencing currently active audible alarms. Any new alarms will cause the audible alarm relay to be activated again and the ACO state canceled.

1.Use the arrow keys to select System Maintenance from the Main Menu. Press Enter or Return.

2.Use the arrow keys to select Execute ACO (Alarm Cut-Off) from the System Maintenance Menu.

3.Press Enter or Return to activate the ACO.

4.The following message appears across the screen and is shown in Figure 539-1.

ACO Executed

Press any key to continue

Stop! You have completed this procedure.

SYSTEM MAINTENANCE

1.Force/APS Commands

2.Reset/LED Test Commands

3.Execute ACO (Alarm Cut-Off)

4.Loopback Status/Commands

5.Di

6.

Di

ACO Executed

7.

Up

Press Any Key To Continue

8.

Te

 

Press CONTROL-A For Assistance

6157-A

Figure 539-1. ACO Executed Message

2-128