ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-541

Page 5 of 16

DS3 MUX LOOPBACK

SELECTION FIELD

High Speed Loopback Status/Commands

Unit Location -

 

 

LOCAL

 

 

===========

 

COMMANDS:

 

 

 

 

 

Loopback :

 

 

 

 

 

STATUS:

 

 

 

 

 

Unit Type:

 

 

DS3MUX

 

 

+---------

+

 

 

 

-----------------

>--------

>-----------------

>

 

 

NETWORK DS3

DEMUX

 

 

<-----------------

<

--------<-----------------

 

fac term

 

 

+---------

+

 

Press CONTROL-A For Assistance

6665-C

Note: Do not perform a DS3 loopback when the Soneplex Broadband chassis

is connected to a DS3 CAM unit in the Soneplex CCAS system.

Figure 541-3. High Speed (DS3 MUX) Loopback Status/Commands Screen

HLXC LOOPBACK

HRX LOOPBACK

HLXR LOOPBACK

SELECTION FIELD

SELECTION FIELD

SELECTION FIELD

 

 

 

Low Speed Loopback Status/Commands

 

 

 

 

 

 

 

Group: 1

 

 

DS1#: 4

 

 

 

 

 

Unit Location -

LOCAL

 

REPEATER

 

REMOTE

 

COMMANDS:

===========

===========

===========

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loopback:

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS:

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Type:

 

 

HLXC

 

HRX1

 

HLXR

 

 

+---------

+

+---------

+

+---------

+

 

 

 

--------------

>--------

>--------

>--------

>--------

>--------

>-------------

>

NETWORK

CUSTOMER

DS1

HDSL

HDSL

DS1

 

 

<--------------

<

--------<--------

<--------

<--------

<--------

<-------------

 

 

net cust

net

cust

net

cust

 

 

+---------

+

+---------

+

+---------

+

 

Programmable Loopback Armed State: ARMING DISABLED

Press CONTROL-A For Assistance

11379-A

Figure 541-4. Low Speed Loopback Status/Commands Screen

2-134

© 2000, ADC Telecommunications, Inc.