ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-570

Page 4 of 18

7.To start a test, set the Measurement field to START. The RTAU waits for pattern sync or frame sync (for framed patterns) before beginning measurement (see Figure 570-15). After syncing, the test begins and the Measurement display changes to RUNNING.

8.As a test progresses, the results are displayed on the RTAU Config screen, in the 'Error Counts' and 'Elapsed Time' columns.

9.To terminate a test, set the Measurement field to STOP. Setting the Mode field to DISABLE also stops any measurements in progress and terminates the test.

10.To end a test session and restore the tested circuit to normal operation, set the Mode field to

DISABLE.

Stop! You have completed this procedure.

 

 

 

 

RTAU CONFIG

 

EQUIPMENT SETUP

 

 

 

 

 

 

===============

 

 

 

 

 

 

Current User

: CRAFT

 

 

Test Circuit: 1-1

Line Code

: INTERNAL

 

 

Mode

: DISABLE

SIGNAL GENERATOR

SETUP

 

 

 

 

======================

 

 

 

 

Pattern Type

: QRS

 

-------------------------------------

Frame Format

: UNFRAMED

 

 

 

 

Loop Code

: NONE

 

 

 

---------------

BIT ERROR SETUP

 

 

Error Counts

Status

Elapsed Time

===============

 

 

============

======

============

Error Count

: 0

Data

:

F Sync:

ES :

Error Rate

: OFF

BPV

:

P Sync:

EFS:

Error Locn

: N/A

Frame:

RAI :

 

 

 

 

CRC

:

 

 

 

 

 

COFA :

 

 

Test Timeout

: 60

Measurement

: STOP

 

In Minutes

 

 

 

 

 

 

Press CONTROL-A For Assistance

14866-A

Figure 570-4. RTAU Config Screen

(Showing Defaults for Screen With Line Code Field Set to INTERNAL)

2-214