ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-573

Page 5 of 6

Table 573-1. HLX Loopback Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

HLXR NID Loopback

Toggle

UNIT SWITCH

Version E HLXR only: Selects

MPU V5.1:

 

 

 

NID setting (enabled) for the

UNIT SWITCH

 

 

 

HLXR.

MPU V5.2:

 

 

 

 

 

 

 

Version D or earlier HLXR:

ENABLED

 

 

 

Selects NID setting (either enabled

 

 

 

 

[default] or disabled) on the HLXR.

 

 

 

 

When the HLXR is provisioned to

 

 

 

 

function like an NID, it supports

 

 

 

 

inband and out-of-band loopback

 

 

 

 

codes.

 

 

 

 

 

 

 

 

ENABLED

Enables response to NID loopback

 

 

 

 

codes and overrides hardware

 

 

 

 

configuration settings.

 

 

 

 

 

 

 

 

DISABLED

Disables response to NID loopback

 

 

 

 

codes and overrides hardware

 

 

 

 

configuration settings.

 

 

 

 

 

 

HLXR Activation

Input

16 binary characters (0’s

16-bit codes can be programmed to

MPU V5.1:

Code

 

and 1’s) must be entered.

any 16-bit binary value except: all 0s,

1100 0111 0100 0010

(“Activation Code” is

 

 

all 1s, or a value that is already used

MPU V5.2:

equivalent to

 

 

in another 16-bit code. The signal is

 

 

1100 0111 0101 0100

“Programmable

 

 

sent inband. HDSL units go to

 

 

 

Code.”)

 

 

loopup state when they are in armed

 

 

 

 

state. Loopup is activated for selected

 

 

 

 

units. Detection time is 3 secs.

 

 

 

 

 

 

HLXR Programmable

Toggle

ENABLED

Enables response to programmable

DISABLED

Lpbk

 

 

loopback codes and overrides

 

 

 

 

hardware configuration settings.

 

 

 

 

 

 

 

 

DISABLED

Disables response to programmable

 

 

 

 

loopback codes and overrides

 

 

 

 

hardware configuration settings.

 

 

 

 

 

 

One HRX in system

Input

16 binary characters (0’s

16-bit codes can be programmed to

1100 0111 0100 0001

only: HRX or HRX1

 

and 1’s) must be entered.

any 16-bit binary value except: all 0s,

No HRX: NOT APPL

Activation Code

 

 

all 1s, or a value that is already used

 

 

 

(“Activation Code” is

 

 

in another 16-bit code. The signal is

 

equivalent to

 

 

sent inband. HDSL units go to

 

“Programmable

 

 

loopup state when they are in armed

 

Code.”)

 

 

state. Loopup is activated for selected

 

 

 

 

units. Detection time is 3 secs.

 

 

 

 

 

 

 

 

 

 

(continued)

2-236