Page 8 of 9
Table
HLXR | # OF HRXS IN | # OF HLXCS IN | MAX. POWER | MAX. POWER | MAX. CURRENT DRAIN |
CONFIGURATION | SYSTEM | CHASSIS | CONSUMPTION | DISSIPATION | (AT |
Span Power ON; | 0 | 1 | 10.5 watts | 6.5 watts | 219 mA |
DS1 simplex |
|
|
|
|
|
disabled; D2A, D4, |
|
|
|
|
|
D4A, D4B, |
|
|
|
|
|
Version E HLXRs |
|
|
|
|
|
|
|
|
|
|
|
|
| 28 | 322 watts | 210 watts | 6.7 amps |
|
|
|
|
|
|
| 1 | 1 | 21.5 watts | 8.5 watts | 448 mA |
|
|
|
|
|
|
|
| 28 | 630 watts | 266 watts | 13.1 amps |
|
|
|
|
|
|
| 2 (Version | 1 | 25.5 watts | 8.5 watts | 531 mA |
| E HLXR |
|
|
|
|
| only) |
|
|
|
|
|
|
|
|
|
|
|
| 28 | 742 watts | 266 watts | 15.4 amps |
|
|
|
|
|
|
Span Power ON; | 0 | 1 | 19.0 watts | 7.5 watts | 396 mA |
DS1 simplex |
|
|
|
|
|
enabled; D1, D2, |
|
|
|
|
|
|
|
|
|
| |
D3B HLXRs |
|
|
|
|
|
|
|
|
|
|
|
|
| 28 | 560 watts | 238 watts | 11.7 amps |
|
|
|
|
|
|
| 1 | 1 | 28.0 watts | 9.5 watts | 583 mA |
|
|
|
|
|
|
|
| 28 | 812 watts | 294 watts | 16.9 amps |
|
|
|
|
|
|
Span Power ON; | 0 | 1 | 5.5 watts | 5.5 watts | 115 mA |
Local power at |
|
|
|
|
|
remote; D1 HLXR |
|
|
|
|
|
|
|
|
|
|
|
|
| 28 | 182 watts | 182 watts | 3.8 amps |
|
|
|
|
|
|
| 1 | 1 | 14.0 watts | 7.0 watts | 292 mA |
|
|
|
|
|
|
|
| 28 | 420 watts | 224 watts | 8.8 amps |
|
|
|
|
|
|
Span Power OFF; | 0 | 1 | 5.5 watts | 5.5 watts | 115 mA |
Local power at |
|
|
|
|
|
remote; D1 HLXR |
|
|
|
|
|
|
|
|
|
|
|
|
| 28 | 182 watts | 182 watts | 3.8 amps |
|
|
|
|
|
|
| 1 | No power values because HRXs require span power. | |||
|
|
|
|
|
|
Note: Power values for a fully configured chassis (28 HLXCs) include the power of the common equipment: APU (7.5 watts), MPU (5 watts), and two DS3 MUX modules (8 watts each), for a total of 28 watts.
© 2000, ADC Telecommunications, Inc.