ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

TAD-101

Page 7 of 9

Table 101-2. DS3 MUX Power Characteristics

MAX. POWER

MAX. CURRENT DRAIN

CONSUMPTION/DISSIPATION

(AT –48 VDC)

8 watts

166 mA

 

 

Note: Two DS3 MUXs (one working and one protect) are used per chassis in Broadband (V5) applications.

Table 101-3. Broadband (V5) Power Characteristics with DLX

NO. OF DLXS IN

MAX. POWER

MAX. CURRENT DRAIN

CHASSIS

CONSUMPTION/DISSIPATION

(AT –48 VDC)

1

2 watts

41 mA

 

 

 

28

84 watts

1.8 amps

 

 

 

Note: Power characteristics for fully configured chassis include common

equipment: APU (7.5 watts), MPU (5 watts), and two DS3 MUX modules (8 watts each), for a total of 28 watts.

Table 101-4. Broadband Power Characteristics with C1 HLXC

HLXR

NO. OF C1 HLXCS

MAX. POWER

MAX. POWER

MAX. CURRENT DRAIN

CONFIGURATION

IN CHASSIS

CONSUMPTION

DISSIPATION

(AT –48 VDC)

Span Powered B1

1

22.7 watts

11.9 watts

473 mA

HLXR with DS1

 

 

 

 

Simplex Disabled

 

 

 

 

 

 

 

 

 

 

28

664 watts

361 watts

13.8 amps

 

 

 

 

 

Span Powered B1

1

28.2 watts

12.4 watts

587 mA

HLXR with DS1

 

 

 

 

Simplex Enabled

 

 

 

 

 

 

 

 

 

 

28

818 watts

375 watts

17 amps

 

 

 

 

 

Local Powered B1

1

8.9 watts

8.9 watts

248 mA

HLXR

 

 

 

 

 

 

 

 

 

 

28

277 watts

277 watts

5.8 amps

 

 

 

 

 

Note: Power characteristics for fully configured chassis include common equipment: APU (7.5 watts), MPU (5 watts), and two DS3 MUX modules (8 watts each), for a total of 28 watts.

2-255