Page 7 of 9
Table
MAX. POWER | MAX. CURRENT DRAIN |
CONSUMPTION/DISSIPATION | (AT |
8 watts | 166 mA |
|
|
Note: Two DS3 MUXs (one working and one protect) are used per chassis in Broadband (V5) applications.
Table
NO. OF DLXS IN | MAX. POWER | MAX. CURRENT DRAIN |
CHASSIS | CONSUMPTION/DISSIPATION | (AT |
1 | 2 watts | 41 mA |
|
|
|
28 | 84 watts | 1.8 amps |
|
|
|
Note: Power characteristics for fully configured chassis include common
equipment: APU (7.5 watts), MPU (5 watts), and two DS3 MUX modules (8 watts each), for a total of 28 watts.
Table
HLXR | NO. OF C1 HLXCS | MAX. POWER | MAX. POWER | MAX. CURRENT DRAIN |
CONFIGURATION | IN CHASSIS | CONSUMPTION | DISSIPATION | (AT |
Span Powered B1 | 1 | 22.7 watts | 11.9 watts | 473 mA |
HLXR with DS1 |
|
|
|
|
Simplex Disabled |
|
|
|
|
|
|
|
|
|
| 28 | 664 watts | 361 watts | 13.8 amps |
|
|
|
|
|
Span Powered B1 | 1 | 28.2 watts | 12.4 watts | 587 mA |
HLXR with DS1 |
|
|
|
|
Simplex Enabled |
|
|
|
|
|
|
|
|
|
| 28 | 818 watts | 375 watts | 17 amps |
|
|
|
|
|
Local Powered B1 | 1 | 8.9 watts | 8.9 watts | 248 mA |
HLXR |
|
|
|
|
|
|
|
|
|
| 28 | 277 watts | 277 watts | 5.8 amps |
|
|
|
|
|
Note: Power characteristics for fully configured chassis include common equipment: APU (7.5 watts), MPU (5 watts), and two DS3 MUX modules (8 watts each), for a total of 28 watts.
© 2000, ADC Telecommunications, Inc.