Page 8 of 13
Table
DS3 MUX ALARMS, AID =
CONDITION | DESCRIPTION |
| BOARD FAIL | Fatal hardware or software error | |
| COMM FAIL | MPU unable to communicate with DS3 MUX | |
|
|
|
|
| CONFIG MISMATCH | Configuration mismatch with mate module | |
|
|
|
|
| PROTECT COMM FAIL | Unable to communicate with mate module | |
|
|
| |
|
| ODS2 ALARMS, AID = |
|
| CONDITION | DESCRIPTION | |
|
|
| |
| BOARD FAIL | Fatal hardware or software error | |
|
|
| |
| COMM FAIL | MPU unable to communicate with ODS2 | |
|
|
| |
| CONFIG MISMATCH | Configuration mismatch with mate module or remote module | |
|
|
| |
| Housekeeping alarm detected at remote end (QFLC or QLX) | ||
| HSKP2 |
|
|
|
|
| |
| PROTECT COMM FAIL | Unable to communicate with mate module | |
|
|
| |
| OPTICAL COMM FAIL | Unable to communicate with remote module | |
|
|
| |
| VERSION MISMATCH | Incompatible software versions with mate module or remote module | |
|
|
| |
|
| ODS2 ALARMS, AID = T1 |
|
| CONDITION | DESCRIPTION | |
|
|
| |
| LOOPED BACK | Signal looped back at either ODS2 or remote | |
|
|
| |
| RECEIVE LOS | Loss Of Signal detected at remote end (QFLC or QLX) | |
|
|
| |
| TRANSMIT LOS | Transmit Loss of Signal detected at remote end (QFLC or QLX), | |
|
| hardware failure | |
|
|
| |
|
| ODS2 ALARMS, AID = T2 |
|
| CONDITION | DESCRIPTION | |
|
|
| |
| APS LIMIT REACHED | APS limit of 3 switches in 24 hours has been reached, APS disabled | |
|
|
| |
| FORCE TO WORK | Working module forced online, APS disabled | |
|
|
| |
| FORCE TO PROT | Protect module forced online, APS disabled | |
|
|
| |
| LASER DEGRADE | Laser driver degradation, hardware failure | |
|
|
| |
| OPTICAL LOF | Optical Loss of Frame | |
|
|
| |
| OPTICAL LOS | Optical Loss Of Signal | |
|
|
| |
| Bit Error Rate exceeds | ||
|
|
|
|
(continued)
© 2000, ADC Telecommunications, Inc.