ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

TAP-101

Page 9 of 13

Table 101-1. Alarm Descriptions/Conditions, continued

HLXC ALARMS, AID = EQPT-LIU#

 

CONDITION

DESCRIPTION

 

 

 

 

 

BOARD FAIL

Fatal hardware or software error

 

 

 

 

 

COMM FAIL

MPU unable to communicate with HLXC

 

 

 

 

 

HLXR INCOMPATIBLE

Incompatible software versions with remote module

 

 

 

 

 

HRX INCOMPATIBLE

Incompatible software versions with HRX

 

 

 

 

 

LOOP REVERSAL

Pairs crossed at HLXR

 

 

 

 

 

TP/RNG REVERSAL

Tip and Ring reversed (either loop)

 

 

 

 

 

PRIMARY POWER

Local power fail indication (1) detected at HLXR

 

 

 

 

 

SECONDARY POWER

Local power fail indication (2) detected at HLXR

 

 

 

 

 

 

HLXC ALARMS, AID = T1

 

 

CONDITION

DESCRIPTION

 

 

 

 

AIS

AIS detected

 

 

 

 

LOOPBACK

Signal looped back toward network

 

 

 

 

LOF

DS1 Loss of Frame

 

 

 

 

LOS

DS1 Loss of Signal

 

 

 

 

T-BERL

DS1 BER threshold crossed (based on BPVs)

 

 

 

 

YEL

Yellow alarm (DS1) detected

 

 

 

 

 

HLXC ALARMS, AID = HDSL

 

 

CONDITION

DESCRIPTION

 

 

 

 

DC CONTINUITY

Loss of loop power DC continuity detected

 

 

 

 

LOF

Loss of Frame (a.k.a. HDSL Loss of Sync Word (LOSW) Failure)

 

 

 

 

RECOVERY

HDSL loop is performing start-up process

 

 

 

 

T-BERP

HDSL loop BER threshold crossed (based on HDSL CRC)

 

 

 

 

T-PA

HDSL Pulse Attenuation threshold crossed.

 

 

 

 

T-SNR

HDSL loop SNR threshold crossed

 

 

 

 

 

HLXC ALARMS, AID = EQPT-EXT#

 

 

CONDITION

DESCRIPTION

 

 

 

 

RMT-HSKP1

Housekeeping contact closure (1) detected at HLXR

 

 

 

 

RMT-HSKP2

Housekeeping contact closure (2) detected at HLXR

 

 

 

 

 

(continued)

2-295