Page 9 of 13
Table
HLXC ALARMS, AID =
| CONDITION | DESCRIPTION | |
|
|
|
|
| BOARD FAIL | Fatal hardware or software error | |
|
|
|
|
| COMM FAIL | MPU unable to communicate with HLXC | |
|
|
|
|
| HLXR INCOMPATIBLE | Incompatible software versions with remote module | |
|
|
|
|
| HRX INCOMPATIBLE | Incompatible software versions with HRX | |
|
|
|
|
| LOOP REVERSAL | Pairs crossed at HLXR | |
|
|
|
|
| TP/RNG REVERSAL | Tip and Ring reversed (either loop) | |
|
|
|
|
| PRIMARY POWER | Local power fail indication (1) detected at HLXR | |
|
|
|
|
| SECONDARY POWER | Local power fail indication (2) detected at HLXR | |
|
|
|
|
|
| HLXC ALARMS, AID = T1 |
|
| CONDITION | DESCRIPTION | |
|
|
| |
| AIS | AIS detected | |
|
|
| |
| LOOPBACK | Signal looped back toward network | |
|
|
| |
| LOF | DS1 Loss of Frame | |
|
|
| |
| LOS | DS1 Loss of Signal | |
|
|
| |
| DS1 BER threshold crossed (based on BPVs) | ||
|
|
| |
| YEL | Yellow alarm (DS1) detected | |
|
|
| |
|
| HLXC ALARMS, AID = HDSL |
|
| CONDITION | DESCRIPTION | |
|
|
| |
| DC CONTINUITY | Loss of loop power DC continuity detected | |
|
|
| |
| LOF | Loss of Frame (a.k.a. HDSL Loss of Sync Word (LOSW) Failure) | |
|
|
| |
| RECOVERY | HDSL loop is performing | |
|
|
| |
| HDSL loop BER threshold crossed (based on HDSL CRC) | ||
|
|
| |
| HDSL Pulse Attenuation threshold crossed. | ||
|
|
| |
| HDSL loop SNR threshold crossed | ||
|
|
| |
|
| HLXC ALARMS, AID = |
|
| CONDITION | DESCRIPTION | |
|
|
| |
| Housekeeping contact closure (1) detected at HLXR | ||
|
|
| |
| Housekeeping contact closure (2) detected at HLXR | ||
|
|
| |
|
| (continued) |
© 2000, ADC Telecommunications, Inc.