HLXC INSTALLATION AND TESTING
Summary: This procedure provides instructions for installing the Version C, D, E, or G HLXC module, which mounts in the
Caution: Modules can be damaged by electrostatic discharge (ESD). Before handling any modules, ESD protection must always be used. Ensure that all modules removed from the chassis or not installed are properly stored in
Note: When using HLXC modules in a group, NEVER install ODS2 modules in any of the unused slots in the group.
1.Select the HLXC module. If it is not already installed, remove the module from its protective ESD packaging. If the HLXC module is installed, remove it and inspect for physical damage.
2.Version C HLXC only: locate the configuration switches on the HLXC module printed circuit board as shown in Figure
3.Version C HLXC only: set the configuration switches as specified in the work order. These switch settings do not need to be set if the unit is to be provisioned via the software. Otherwise, refer to Figure
•Loop 2 (enable/disable)
•Loop Power (on/off)
Note: With loop 2 enabled, both HDSL loops will be active allowing a full DS1 payload. With loop 2 disabled, the first 12 DS0 channels will be carried on loop 1 and DS0 channels 13 through 24 will be filled with all ones (fractional DS1).
Note: When the Loop Power switch is set to the ON position, the HLXC module supplies
4.Determine which HLXC slots are to be used, referring to your work order and Figure 516- 2. Chassis slots
Reference: