ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-522

Page 2 of 2

10.At the far end of the circuit, insert a DS1 test signal into the DS1 input using the DS1 test set.

11.Verify that all alarm indicators on the chassis are off and the DS3 test set with DS1 option is receiving error-free data in the DS1 signal selected for test.

12.Repeat Steps 10 and 11 for all DS1 circuits to be tested.

Stop! You have completed this procedure.

 

 

DSX-3

 

 

 

CROSS-CONNECT

SONEPLEX

 

 

 

 

 

 

BROADBAND

 

DS3 TEST SET

MON

CHASSIS

 

RX

 

TX

 

 

 

 

 

OUT

DS3

 

 

 

 

TX

IN

RX

 

 

 

 

 

 

 

DSX-1

 

SONEPLEX

 

CROSS-CONNECT

 

 

 

 

BROADBAND

OFFICE EQUIPMENT

 

CHASSIS

 

 

MON

 

 

 

 

TX

DS1 TEST SET

DLX

OUT

or

RX

RLX

 

RX

IN

 

TX

6186-B

Figure 522-1. Test Setup

2-73

© 2000, ADC Telecommunications, Inc.