Page 1 of 2
DLX- OR
Summary: This procedure provides instructions for performing
Warning: To prevent electric shock and/or equipment damage, disable span power at the RLX module before performing this test.
1.At the chassis, identify the DLX or RLX pair that corresponds to the DS1 circuit to be tested.
Reference: | DLX Configuration | |
Reference: | RLXIOR Configuration | |
Reference: | RLX Configuration |
2.At the chassis, connect a DS3 test set with DS1 option to the
3.At the far end of the circuit, identify the DS1 pair that corresponds to the circuit to be tested.
4.At the far end of the circuit, connect a DS1 test set to the circuit to be tested at the DS1 input and output connections, the DS1 patch panel, or at the
5.At both ends of the circuit to be tested, make necessary
6.Using the Craft Interface, verify that the modules are EQUIPPED and IN SERVICE.
Reference: | DS3 MUX Configuration | |
Reference: | DLX Configuration | |
Reference: | RLXIOR Configuration | |
Reference: | RLX Configuration |
7.At the chassis location, insert a test signal into the DS1 to be tested using the DS3 test set with DS1 option.
8.Verify that all alarm indicators on the chassis are off and the DS1 test set at the far end DS1 output is receiving
9.Repeat Steps 7 and 8 for all DS1 circuits to be tested.
© 2000, ADC Telecommunications, Inc.