DLX INSTALLATION AND TESTING
Summary: This procedure provides instructions for mounting DLX modules in the
Caution: Modules can be damaged by electrostatic discharge (ESD). Before handling any modules, ESD protection must always be used. Ensure that all modules removed from the chassis or not installed are properly stored in
Note: When using DLX modules in a group, NEVER install ODS2 modules in any of the unused slots in the group.
1.Remove the module from the protective packaging if required. Refer to your work order and determine which DLX slots are to be used. DLX chassis slots are shown in Figure
Reference:
2.Align module with the slots and slide module into the chassis. Using the ejector, press the DLX module into the chassis until it is properly seated.
3.Press LMPTST switch on the APU. Are all indicators lighted?
•If Yes, continued to Step 4.
•If No, replace DLX module and go to Step 1.
4.Repeat entire procedure for each DLX module.
Stop! You have completed this procedure.