HLXC AND HLXR
Summary: This procedure provides instructions for using a DS3 test set (with DS1 option) to verify that
Caution: Modules can be damaged by electrostatic discharge (ESD). Before handling any modules, ESD protection must always be used. Ensure that all modules removed from the chassis or not installed are properly stored in
Note: Press
1.Connect a DS3 test set (with DS1 option) to the
2.Identify the HLXC module corresponding to the DS1 circuit to be tested.
3.Identify the HLXR module corresponding to the DS1 circuit to be tested.
4.Connect the DS1 Test Set RX to the NET OUT jack on the front panel of the HLXR module.
5.Connect the DS1 Test Set TX to the NET IN jack on the front panel of the HLXR module.
6.Using the Craft Interface, verify that the DS3 MUX is EQUIPPED and is IN SERVICE.
Reference:
7.Using the Craft Interface, verify that the HLXC module to be tested is EQUIPPED and IN SERVICE and the DS1 to be tested is PROVISIONED and IN SERVICE.
Reference:
8.Insert a test signal into the DS1 to be tested using the DS3 test set with DS1 option.
9.Verify that all alarm indicators on the chassis are out and the DS1 test set at the HLXR module NET OUT jack is receiving
10.Insert a DS1 test signal into the HLXR module NET IN jack using the DS1 test set.
11.Verify that all alarm indicators on the chassis are out and the DS3 test set with DS1 option is receiving
12.Repeat procedure starting at Step 2 for all HLXC modules to be tested.
13.Record test results and update office records following local office practices.
Stop! You have completed this procedure.