ADCP-75-214 • Issue 2 • September 2006

4.4Troubleshooting Matrix

If directed in Section 4.3 to consult a troubleshooting matrix, see Table 1 below.

Note: ClearGain PDU DIP switches must be in the down position for each active MHU!

Note: ClearGain PDU input voltage must be in the range –56 to –20 VDC or +20 to +56 VDC.

Table 1. Troubleshooting Matrix

 

 

 

GREEN/YELLOW

RED GENERAL

PARAMETER

SPECIFICATION

EXPLANATION

OK LED

ALARM LED

Electronic Load

 

 

 

 

 

 

 

 

 

Each Path OFF

< 180 mA

Fail

OFF

ON

 

 

 

 

 

Each Path ON

180 – 220 mA

OK

GREEN

OFF

 

 

 

 

 

Total Fail

370 – 400 mA

Fail

OFF

ON

 

 

 

 

 

Short Circuit

1.5 A ± 10%

Fail

GREEN

ON

Protection

 

 

 

 

Short state of MHU path does not affect other path. After generating Green alarm,

 

 

the short state is held for ten seconds then Red alarm is generated by the PDU.

 

 

 

 

 

Circuit Fluctuation

Min 180 mA

One path failed.

YELLOW

ON

 

Max 380 mA

 

 

 

 

 

 

 

 

Input Voltage

–56 to –20 VDC /

OK

GREEN

OFF

 

+20 to +56 VDC

 

 

 

 

 

 

 

 

Output Voltage

15 V, 4%

Total failure.

OFF

ON

 

 

 

 

 