5.3PDU (Power Distribution Unit)
Table 4 provides typical specifications for the PDU.
Table 4. Power Distribution Unit (PDU) Specifications
CATEGORY | PARAMETER |
| SPECIFICATION | |
Electrical | Input voltage range |
| ||
|
|
|
| (Input polarization protected) |
|
|
|
| |
| Output voltage |
| 15V, 4% (Over voltage protection) | |
|
|
| ||
| Output voltage accuracy | 4% in 20mA – 400mAMAX 10% in 1.5A | ||
|
|
|
| |
| Output ripple |
| 100mV pk – pk | |
|
|
|
| |
| PDU Inrush Current |
| ||
|
|
| ||
| Short circuit protection | 1500mA, 10% | ||
|
|
|
| |
Connector and | Outputs for TMA's |
| SMB connector Male (3 pcs) | |
LED |
|
|
|
|
Input connector |
| Molex | ||
|
| |||
|
|
| ||
| General alarm connector | Molex | ||
|
|
| ||
| Communications link between BTS | Molex | ||
| and RET |
|
| |
|
|
|
| |
| Indicators |
| Two color LED (3 pcs) (green and yellow) | |
|
|
|
| Red LED 1 pcs |
|
|
| ||
Physical | Dimensions (W x H x D) | 194.4 x 43.6 x 100.0 mm | ||
|
|
|
| (7.7 x 1.7 x 3.9 inches) |
|
|
|
| |
| Weight |
| 0.5 Kg (1.2 lbs.) | |
|
|
|
| |
| Color |
| Gray Metallic | |
|
|
|
| |
Communication | Pin Number |
| Signal | Comments |
|
|
|
|
|
| 1 |
| RS485 A | RET control command AISG Layer2. ISO/ |
|
|
|
| IEC 8482:1993 (RS485). |
|
|
|
|
|
| 2 |
| RS485 B |
|
|
|
|
|
|
| 3 |
| RS485 GND |
|
|
|
|
| |
| PDU only receives control command from BTS and modulates 2.176MHz Modem | |||
| Signal and transmit to TMA through SMB connector, and vice versa. | |||
|
|
| ||
| Resistance between RS485 A and | > 1k Ohm | ||
| RS485 B |
|
| |
|
|
| ||
| Resistance between RS485 A or | > 1k Ohm | ||
| RS485 B and DC return / RS485 GND |
| ||
|
|
| ||
| Capacitance between RS485 A or | < 1nF | ||
| RS485 B |
|
| |
|
|
| ||
| Capacitance between RS485 A or | < 1nF | ||
| RS485 B and DC/RS485 GND |
| ||
|
|
|
|
|
Page 20
© 2006, ADC Telecommunications, Inc.