Appendix C - Ground Faults | |
|
|
APPENDIX C - GROUND FAULTS
GROUND FAULT DETECTION
The
When used with HiGain line units, ground faults occurring at any point along any span are immediately detected. Ground fault conditions shut the HiGain circuit down. The line unit periodically tries to apply power to the first span to determine whether the fault condition is still present. As long as the condition exists, the power cycling and ground fault protection continues. To discontinue the ground fault protection, locate and repair the fault in the cable.
Circuits containing both the
To operate properly, the ground fault circuit requires that the doubler enclosure ground plane be securely connected to earth ground. Failure to do so can cause false triggering of the GFD circuit.
April 30, 2003 | 29 |