Spec Sheet

The Radiator II Below Ground HDSLx 8-Slot Repeater Housing is designed to withstand hostile conditions, improve thermodynamic performance and reliability of the outside plant electronics in 50 percent less manhole space than traditional enclosures. It includes a 30-foot, 100-pair air core screened, dual armor cable stub.

ceNtRAL OFFIce

 

OSp

 

OSp

cUStOMeR pReMISeS

 

eLectRONIcS

 

 

 

 

 

 

eLectRONIcS

 

 

 

 

RADIAtOR

 

RADIAtOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Repeaters

 

Repeaters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications

Housing Construction, Lid:

Non-corrosive 18-gauge seamless, 316 stainless steel, painted white

Capacity:

Supports 8 single or a maximum of 6 double wide HDSL, HDSL4,

 

G.SHDSL, T1, ISDN and DDS repeaters

Ambient Temperature Range:

–40˚F to +149˚F (–40˚C to +65˚C)

Relative Humidity:

100% when pressurized

Pressurization:

12 psi maximum – pressure relief valve

Security:

V-band may be secured with a padlock

Dimensions:

Diameter 12.5”, housing and mounting bracket together 14.25” high

Weight (without modules/cable stub):

Approximately 28 lbs.

Mounting:

Backboard or underground rack mount

Lightning Protection:

Three-element gas tube

Safety Standards Compliance:

Equipment tested and verified to comply with the following standards:

GR 63-CORE:

Network Equipment-Building System (NEBS) Requirements

GR 487-CORE:

Generic Requirements for Electronic Equipment Cabinets

GR 950-CORE:

Generic Requirements for Optical Network Unit (ONU) Closures

TR-TSY-000056:

Repeater Housings for T1, T1C, T1D, and T1G Carrier Systems

FCC Part 15:

Electrical Safety

Binational Standard:

UL-60950/CSA C22.2 No. 950-95: Safety of Information

 

Technology Equipment

O r d e r i n g I n f o r m a t i o n

Description

Catalog Number

 

 

Radiator II 8-Slot Below Ground HDSLx Repeater Housing

RAD-BA30-8

30’ air core stub, pressurized

 

 

 

Website: www.adc.com

From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080

Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.

ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101

Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer

106823AE  8/08  Revision  ©  2008, 2005, 2004  ADC Telecommunications, Inc.  All Rights Reserved