FRONT PANEL
CONNECTIONS
A
| BACKPLANE |
| CONNECTIONS |
B |
|
A | J1 |
| A |
| B |
B | J2 |
| LED/ALARM |
| ELECTRONICS |
| |
| ONLY) |
| J3 DCE |
C |
|
|
Figure
3.1PS Control Module
The PS Control Module (CM) controls the overall manual operations of the modules contained in the PS chassis. Three toggle switches located on the front panel have the following functions:
1.Bank switch all PS modules to either the “A” or “B” position. That is, switch all modules at the same time to either the “A” position or “B” position.
2.Enable the bank switch and the individual module A/B switches.
3.Reset all of the modules' alarm circuits.
The audible alarm circuitry is in the CM. It activates when an individual PS module detects an alarm condition (according to the alarm selection configuration on the module). Alarm conditions are detected only by modules which contain circuitry. The alarm circuitry must also be conditioned by proper strapping (jumper) of the individual PS chassis module.
When the alarm condition occurs, the individual module energizes its yellow LED indicator and the CM audible alarm sounds. The operator toggles the reset switch to reset the alarm circuitry.
The PS Control Module is equipped with a selectable remote control feature. Depending on the strap position the CM will either accept serial
With the CM strapped for serial
1.PatchSwitch Remote Control Unit (RCU,
2.Terminal or computer (asynchronous ASCII device).
Page
© 1999, ADC Telecommunications, Inc.