Table
NAME | FUNCTION | USED ON | |
AB MASTER | A/B switch operates all 16 chassis modules | PS Chassis Control | |
Momentary Toggle | with A/B switching function to the A or B | Module | |
| DTE channel position. |
| |
|
|
| |
ENABLE | In either up or down position, enables operator |
| |
Momentary Toggle | to make an A/B switch (both channel and |
| |
| gang). |
| |
|
|
| |
ALARM RESET | In either up or down position, enables operator to |
| |
Meomentary Toggle | reset PS chassis modules alarm(s) from on to off. |
| |
|
|
| |
AB Momentary | Allows operator to switch from channel A to B or B | All Switch Modules | |
Toggle Switch | to A. |
| |
|
|
| |
RST Touch | Allows operator to reset alarm. | All Modules with | |
|
| Alarm Capability | |
Alarm Three Position | Allows operator to select OFF (LED off; audible | ||
| |||
OFF/ALM/LED | alarm off), ALM (LED and audible alarm on), and |
| |
| LED (LED on, audible alarm off). |
| |
|
|
| |
DLY alarm Delay | Allows operator to select eight different time delays |
| |
Eight Position Rotary | for alarm operation. |
| |
|
|
|
6 CONTROL MODULE SWITCHING (LOCAL)
The switch function designators for the three momentary toggle switches located on the front panel of the control module are termed:
1.A/B MASTER
2.ENABLE
3.ALARM RESET
6.1Interface Converter Module
The Interface Converter Module is used in conjunction with the Control Module to provide compatibility between a PatchSwitch Control Module and an
6.2Single Channel Switching
To switch a PS module, the operator toggles the ENABLE switch to either
Page
© 1999, ADC Telecommunications, Inc.