6.3Bank Switching
Bank switching is performed by the operator toggling the A/B MASTER switch (located on the Control Module) to either the A or B position and then toggling the ENABLE (directly below the A/B MASTER switch) switch
Bank switching starts with module 0 (slot l) and ends with PS chassis module 15 (slot 16). The individual module A/B switches are disabled while the A/B MASTER switch is toggled in either the A or B position.
6.4Reset Alarms
To reset the module alarms, the operator toggles the ALARM RESET switch (located on the Control Module) to either
The alarm reset function clears all the alarm circuits. An individual module alarm circuit may be selectively reset by touching the two posts on the alarming module.
6.5DC Pulse Control Switching
The PatchSwitch Control Module is capable of Bank switching the PS chassis modules which perform A/B switching by responding to dc voltage pulses received over the communications channel from a remote device. In order to enable dc pulse control, the remote control jumper block must be set to the dc pulse control selection. Bank switching via (signal ground), +5V or
Note: If a “switched to” A dc voltage level is applied while a “switched to” B dc voltage level is active, all modules will switch to the A position but will be restored to the B position after the “switched to” A signal is removed, provided the “switched to” B signal remains active.
As with front panel bank switching, all modules in the PS chassis will switch to the channel (A or B) corresponding to the dc voltage applied per Table
Bank switching starts with module 0 (slot 1) and ends with PS module 15 (slot 16). The individual module A/B switches are disabled while the dc voltage is present.
Page
© 1999, ADC Telecommunications, Inc.