Safety information

Safety information

For use in dry, oil free indoor environments only.

Do not use to link between buildings.

Not suitable for use in hazardous or explosive

 

environments or next to highly flammable

 

materials.

Ensure that all twisted pair interconnect cables

 

are installed in compliance with all applicable

 

wiring regulations.

Do not connect the CATx link interface (RJ45

 

style connector) to any other equipment,

 

particularly network or telecommunications

 

equipment.

If you use a power extension cable with the

 

modules, make sure the total ampere rating of

 

the devices plugged into the extension cable

 

do not exceed the cable’s ampere rating. Also,

 

make sure that the total ampere rating of all the

 

devices plugged into the wall outlet does not

 

exceed the wall outlet’s ampere rating.

Do not attempt to service the modules yourself.

The modules and power supplies can get

 

warm in operation – do not situate them in an

 

enclosed space without any ventilation.

The modules do not provide ground isolation

 

and should not be used for any applications that

AdderLink AV

Quick Start

What’s in the box

Where possible, avoid laying the twisted pair

 

link cable(s) alongside power cables.

Warning – the power adapter contains live

 

parts.

No user serviceable parts are contained within

 

the power adapter - do not dismantle.

The primary means to cease operation of the

 

modules is to remove the power adapter lead.

 

Ensure that the power adapter is positioned

 

near to the equipment and is easily accessible.

Do not use the power adapter if the power

 

adapter case becomes damaged, cracked or

 

require ground isolation or galvanic isolation.

Use only with grounded outlets at both the

 

computer and monitor. When using a backup

 

power supply (UPS), power the computer, the

 

monitor and the module from the same supply.

For correct operation, the transmitter

 

and receiver modules must have ground

 

connections. At the computer end, this is

 

achieved by ensuring that the computer that

 

the module is connected to has a ground

 

connection. At the audio/visual device end, this

 

can be achieved by ensuring that the power

ADDERLINK

IN

IN

AdderLink AV transmitter*

0 10

TRANSMITTER

ADDERLINK

OUT

OUT * AdderLink AdderLink AVQuick StartWhat’s in the boxWarrantyWhat you may additionally needConnection overview insideManual background

AV100 and Manual backgroundManual backgroundManual background AV200 models are both

packaged as transmitter and

receiver pairs. AV104, AV101, AV100R and AV100T modules are packaged separately.

0 10

RECEIVER

AdderLink AV receiver*

broken or if you suspect that it is not operating

properly.

• Replace the power adapter with a manufacturer

approved type only.

supply is connected to a grounded power

outlet. Alternatively, a ground connection will

be made via the monitor, if the monitor is itself

grounded.

For each module: Power supply adapter and country-specific mains cable

Warranty

Adder Technology Ltd warrants that this product shall be free from defects in workmanship and materials for a period of two years from the date of original purchase. If the product should fail to operate correctly in normal use during the warranty period, Adder will replace or repair it free of charge. No liability can be accepted for damage due to misuse or circumstances outside Adder’s control. Also Adder will not be responsible for any loss, damage or injury arising directly or indirectly from the use of this product. Adder’s total liability under the terms of this warranty shall in all circumstances be limited to the replacement value of this product. If any difficulty is experienced in the installation or use of this product that you are unable to resolve, please contact your supplier.

Adder Technology Limited,

Adder Corporation,

Email: support@adder.com

Technology House,

29 Water Street,

Web: www.adder.com

Trafalgar Way, Bar Hill,

Newburyport,

 

Cambridge, CB3 8SQ,

MA 01950,

 

United Kingdom

United States of America

 

Tel: +44 (0)1954 780044

Tel: +1-888-932-3337

 

Fax: +44 (0)1954 780081

Fax: +1-888-275-1117

 

© 2005 Adder Technology Limited • Release 1.0a • October 2005 • Part No. ADD0060

All trademarks are acknowledged. Documentation by Corporate Text & Design (www.ctxd.com)

 

CD-ROM

Self adhesive

containing skew

rubber feet

test pattern and

 

documentation

What you may additionally need

Stereo audio cable

Adder: P/N VSC22

Video cable

Adder P/N: VSC18

Serial cable

Adder P/N: CAB-9M/9F-2M

Connection overview inside

Full user guide available on the CD-ROM and also at www.adder.com