16
NOTE: For security reasons, your installer may program the syst em to pre-
vent you from turning off certain detectors (for example, smoke detectors).
NOTE: If you have 24-hour zones (zones that are continuously on) on your
system, they will stay bypassed until you turn off the bypass using the steps
above (ask your installer for more information).
Checking
Trouble
Conditions
Your system continuously checks for a number of possible trouble conditions. If
one of these trouble conditions occurs:
The yellow (Trouble) light will be ON until the Trouble is corrected.
The keypad will beep twice every 10 seconds until it is acknowledged by press-
ing the key.
A Trouble condition reduces the level of security your system provides. Call your
installing company for service.
To view the Troubles that are present, press .
To exit the Trouble menu, press .
Here is a list of the various Trouble conditions that may occur:
Display: Problem and how it should be addressed:
[1] Service required
Press [1].
If this number appears, call for service. It represents one or more
of the following Troubles:
1Low Battery Low Battery means the battery voltage has
fallen below the normal operating voltage.
2 Not Used
3General System
Trouble
Indicates that a peripheral device has a system
fault.
- NT9204 Supply Trouble.
- NT9204 Output Fault.
- RF Jam Verified.
4General System
Tam p e r
Indicates that a peripheral device has been tam-
pered with.
5General System
Supervisory
Indicates that a peripheral device can not com-
municate with the system.
6RF Jam RF Jam indicates interference from an RF (Radio
Frequency) source.
7NT9204
Low Battery
Indicates that the battery voltage has fallen
below the normal operating voltage on the
NT9204 module.
8NT9204
AC Fail
Indicates AC voltage failure on the NT9204
module.
#
2
*
#