NOTE: The Gig abit Ethernet port(s) are optical and
therefore are not classified as any type of port as
defined in Appendix B of GR-1089-CORE Issue 4.
The SFP is designed to meet the following environmental
classes:
♦ETSI EN 300 019-1-1 “Classification of
environmental conditions; Storage,” Class 1.2
♦ETSI EN 300 019-1-2 “Classification of
environmental conditions, Transportation,” Class 2.3
♦ETSI EN 300 019-1-3 “Classification of
environmental conditions, Stationary use at weather-
protected locations,” Class 3.3
The equipment is designed to function without degra-
dation during exposure to all test severities per Class 3.3.
COMPLIANCE
CAUTION: Electrostatic Discharge (ESD) can damage
electronic modules. When handling modules,
wear an antistatic discharge wrist strap to
prevent damage to electronic components. Place
modules in antistatic packing material when
transporting or storing. When working on
modules, always place them on an approved
antistatic mat that is electrically grounded.
The SFP is NRTL Listed to the applicable UL
standards. The SFP meets or exceeds all the
applicable requirements of NEBS, Telcordia
GR-63-CORE, and GR-1089-CORE. The SFP is
intended for deployment in Central Office type
facilities, EEEs, EECs, and locations where the
NEC applies (for example, Customer Premises
and is intended to be installed by trained
service personnel). Install the SFP in an
ADTRAN product located in a restricted access
location.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by
ADTRAN could void the user's authority to operate this
equipment.
CAUTION: Per GR-1089-CORE the ADTRAN system that
the SFP is being deployed in is designed and
intended for installation as part of a Common
Bonding Network (CBN). The ADTRAN system
that the SFP is being deployed in is not designed
nor intended for installation as part of an
Isolated Bonding Network (IBN).
Per GR-1089-CORE Section 9, the SFP does not
have an internal DC connection between battery
return and frame ground. The SFP can be
installed in a DC-I (isolated) or DC-C (common)
installation. For installations where other cards
or the host system have internal connections
between battery return and frame ground, the
system would be intended for deployment only
in a DC-C installation.
The ADTRAN system chassis frame ground
terminal must be connected to an earth ground to
ensure that the metal enclosure of the SFP is
properly grounded via the backplane connector.
Warranty: ADTRAN will replace or repair this product within the w arranty period if it does not meet
its published specifications or fails while in service. Warranty information can be found
online at www.adtran.com/warranty.
© 2008 ADTRAN, Inc. All Rights Reserved.
*61442140G1-22A*
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
CLEI: VAUIAMAP _ _
Product P/N: 1442140G1
Issue Date: 0804
Document P/N: 61442140G1-22A
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
Small Form-Factor PluggableGigabit Ethernet, Single-Mode 40 km