for access during maintenance. Note clearances required for removing the Environmental Housing. See Figure 2 for mounting clearances.
2.Place the mounting bracket 3/4" spacers between the rear of the mounting bracket and the mounting surface. The spacers are required to insure the mounting bracket is not warped during installation or use.
3.Insert the 1/4" x 11/2" Hex head lag screws through the mounting holes of the mounting bracket and spacers. Tighten securely with a 7/16" nut driver.
9.0" |
|
8.5" |
|
1.0" | 1.0" |
6.0" |
|
Figure 2. Clearances
Install the T400 Environmental Housing
1.Fasten the Environmental Housing to the mounting bracket using the two mounting bracket bolts.
2.Tighten the two bolts using a 7/16" nut driver to 25
Power Modules in the central office should be removed or
personal safety.
Network Wiring
1.Remove the network cover on the base using a 7/16" nut driver.
2.Connect the wiring in the terminal blocks as shown in Table A. The terminal block will accommodate a #6 Spade Lug.
Mounting |
Holes |
5 3/8 " |
3/4" |
43/16 " |
Figure 3. Mounting Holes
3.Connect the ground cable to an appropriate ground. (Surge arrestors work only when the ground cable is connected.)
4.Replace the network cover on the base using a 7/16" nut driver. Tighten to 20
Customer Wiring
1.Remove the customer cover on the base using a
2.Connect the wiring in the terminal blocks as shown in Table A. The terminal block will accommodate a #6 Spade Lug. The terminal blocks are shown in Figure 4.
3.Replace the customer cover on the base using a
5 | 15 | 49 55 NC | 7 | 13 | 41 47 | 11 |
CUSTOMER ACCESS |
|
| WARNING! |
| ||
| COVER TO BE | |||||
|
|
| REMOVED BY TELEPHONE | |||
|
|
| COMPANY PERSONNEL | |||
NETWORK INTERFACE DEVICE |
|
| ONLY |
|
Figure 4. Wiring Terminals
Remove the Environmental Housing Cover
1.Wipe any debris from the cover and base.
2.Remove the two housing cover bolts using a 7/16" nut driver.