HTU - C / DDM +

JOBAID

61246003L2-22B

 

0003

 

 

HTU-C / DDM+

CLEI: T1L3B5BA_ _

HTU-CM1246003L2

STATUS LEDs

STATUS

RED

Alarm on any HTU-C loops, HRE loops, DSX or DS1 interface

 

FLASHING

Signal Quality of 0 or No Sync on at least one loop

 

YELLOW

Loopbacks active

 

FLASHING

In-band loopbacks armed

 

GREEN

Functioning properly

 

FLASHING

ES, SES, or BPV detected at either DSX or DS1 interface

RS-232 DB-9 CONNECTOR

Used to access the HDSL utilities menu tree via VT100 emulation software such as terminal, Hyper Terminal – Private Edition and ProComm Plus.

Provision terminal port as follows:

HARDWARE SWITCHES

SW1

Rotary switch sets the DSX-1 line build out

00 — sets LBO to 0-133 feet

1133 — sets LBO to 133-266 feet

2266 — sets LBO to 266-399 feet

3399 — sets LBO to 399-533 feet

4533 — sets LBO to 533-655 feet

Note: Positions 5,6 & 7 are not used.

SW2

Data Rate — 9.6 kbps, 19.2 kbps

Is used to provision the card. Default settings are in bold.

Asynchronous Data Format — eight data bits, no parity (none), one stop bit

 

 

Hardware Flow Control should be disabled.

SW2-1

— sets the line code to either AMI or B8ZS

SW2-2

— sets the T1 framing to either Unframed or Framed

When using a PC with terminal software, be sure to disable any power saving programs.

 

 

Note: Unframed operation ignores the setting of SW2-3.

STATUS

R S 2 3 2

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

COMPLIANCE CODES

This product complies with UL 1459, third edition. It is intended to be installed in an enclosure with an Installation Code (IC) of “B” or “E” and in Restricted Access Locations only. Input current at maximum load is 0.7 A. Output ratings on the net- work are maximum 165 mA at -190 Vdc.

Code

Input

Output

Power Code (PC)

F

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

WARRANTY

Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of ADTRAN’s U.S. and Canada Carrier Network Equipment Warranty: (877) 457-5007, Document #414.

SW2-3 — sets the T1 framing to either SF or ESF SW2-4 — Enables or disables the NIU loopback option SW2-5 — Enables or disables the Loopback Timeout option

Default timeout setting is 20 minutes

Must be enable prior to initiating a loopback

SW3

Selects the span powering voltage

LV — selects –140 Vdc to span power a single HTU-R or

one HRE and an HTU-R

HV — selects –190 Vdc to span power two HREs and an

HTU-R

HANDLING PRECAUTIONS REQUIRED.

For complete Installation and Maintenance: (877) 457-5007, Document #461. Please have your fax number available.

Page 1
Image 1
ADTRAN HDSL HTU-C/DDM+ warranty RS-232 DB-9 Connector, Hardware Switches, Compliance Codes, Warranty