ADTRAN SHDSL V.35 LTU manual SHDSL V. 35 LTU, Jobaid, Total Access, Shdsl, Interface Connections

Models: SHDSL V.35 LTU

1 2
Download 2 pages 17.47 Kb
Page 1
Image 1
TOTAL ACCESS

TOTAL ACCESS

®

3000 SHDSL V. 35 LTU

JOBAID

 

61182008L5-22A

 

 

 

0202

 

 

 

 

TOTAL ACCESS 3000 SHDSL V.35 LTU

SHDSL

1182008L5

N

x 6 4 K

RX

3000 SHDSL V. 35 LTU PWR

FRONT PANEL LED INDICATORS

PWR

Off

No power

 

Green

Self-test passed and the module is In Service

 

Yellow

Self-test passed and the module is Out of Service

SHDSL Off

SHDSL Loop is Out of Service -- Unassigned

 

Green

SHDSL Loop is trained

G.703

Red

SHDSL Loop is not trained

Off

G.703 port is not configured, Out of Service -- Unassigned, or in alarm

 

 

condition

Nx64k

Green

G.703 port configured and no alarms

Off

Service is not configured or in alarm condition

RTS

Green

Service is configured and operating normally

Off

Nx64k service not configured or RTS control line is OFF

RLSD

Green

RTS control line is ON

Off

Nx64k service not configured or RLSD control line is OFF

TST

Green

RLSD control line is ON

Off

Module is not in loopback or BERT

 

Green

Local loopback is active, or BERT running with no errors

 

Blinking Yellow

Module is running a BERT with bit errors

ALM

Red

BERT running with no pattern sync

Off

No alarm condition detected

 

Yellow

Remote alarm condition detected

 

Red

Alarm condition detected locally

V.35 PORT PIN ASSIGNMENTS
V.35 Port

 

 

 

Circuit No.Circuit Name

To/From DCE

Pinout (A/B)

102

Signal Ground

 

B

103

Transmit Data

To

P/S

104

Receive Data

From

R/T

105

Request To Send

To

C

DEFAULT PROVISIONING OPTIONS
Provisioning

 

OptionsDefault

 

 

 

 

Unit Options

 

 

 

Cross-Connect Map

 

 

All Idle

Local Management

 

Disabled, Enabled

Enabled

LT Mode Clk Source

 

Internal Clock

Internal Clock

 

 

Nx64 ETC

 

 

 

G.703 RX Clock

 

NTU Auto Provisioning

 

Disabled, Enabled

Disabled

External Port Alarms

 

Disabled, Enabled

Enabled

Line Card Service State

 

In Service

Out of Service - Unassigned

 

Out of Service - Maintenance

 

 

Out of Service - Unassigned

 

G.703 Port Service State

 

In Service

Out of Service - Unassigned

 

Out of Service - Maintenance

 

 

Out of Service - Unassigned

 

Nx64K Port Service State

 

In Service

Out of Service - Unassigned

 

Out of Service - Maintenance

 

 

Out of Service - Unassigned

 

SHDSL Options

 

 

 

Rate (Kbps)

Enter a new value for N from 3 to 36,

2056 (N=32)

 

where Rate(Kbps)=(N x 64) + 8:

 

SNR Margin Alarm Threshold(dB)

Disabled, Enabled

Disabled

Loop Attenuation Alarm Threshold (dB)

Disabled, Enabled

Disabled

Test Options

 

 

 

Loopback Timeout(Min)

 

Disabled, Enabled

Disabled

BERT Test Pattern

 

All Zeros

2e15-1

 

 

All Ones

 

 

 

2e15-1

 

 

 

2e23-1 2e15-1

 

G.703

SHDSL

106

Clear To Send

From

D

BERT Test Pattern Polarity

Normal, Inverted

Normal

JOBAID G.703

61182008L5-22A Nx64K

TX

0202 RTS

TOTAL ACCESS 3000 SHDSL V.35 LTU RLSD

SHDSL TST

FRONT PANEL LED INDICATORS ALM

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

107

Data Set Ready

From

E

108/2

Data Terminal Ready

To

H

109

Received Line Signal Detect

From

F

113

Transmit Signal Element Timing

To

U/W

114

Transmit Signal Element Timing

From

Y/AA

115

Receive Signal Element Timing

From

V/X

140

Remote Loopback

To

N

141

Local Loopback

To

L

142

Test Indicator

From

NN

INTERFACE CONNECTIONS

The G.703 signal is transmitted to the network either via the Total Access 3000 backplane connectors or the two BNC connectors mounted on the faceplate. The G.703 signal and the SHDSL signal use the following backplane amphenol connector Pairs:

SHDSL - Pair 2

G.703 Tx - Pair 8

G.703 Rx- Pair 7

Nx64K In-band Pattern Detection

Disabled, Enabled

Disabled

COMPLIANCECaution: Up to -200 VDC may be present on telecommunications wiring.

This product is intended for installation in restricted access locations only and in equipment with a Type “B” or “E” enclosure.

Code

Input

Output

Power Code (PC)

F

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

HANDLING PRECAUTIONS REQUIRED.