![TOTAL ACCESS](/images/new-backgrounds/140693/1406931x1.webp)
TOTAL ACCESS | ® | 3000 SHDSL V. 35 LTU | JOBAID |
| |||
|
|
| 0202 |
|
|
|
|
TOTAL ACCESS 3000 SHDSL V.35 LTU
SHDSL
1182008L5
N
x 6 4 K
RX
PWR
PWR | ● Off | No power |
| ● Green | |
| ● Yellow | |
SHDSL ● Off | SHDSL Loop is Out of Service | |
| ● Green | SHDSL Loop is trained |
G.703 | ● Red | SHDSL Loop is not trained |
● Off | G.703 port is not configured, Out of Service | |
|
| condition |
Nx64k | ● Green | G.703 port configured and no alarms |
● Off | Service is not configured or in alarm condition | |
RTS | ● Green | Service is configured and operating normally |
● Off | Nx64k service not configured or RTS control line is OFF | |
RLSD | ● Green | RTS control line is ON |
● Off | Nx64k service not configured or RLSD control line is OFF | |
TST | ● Green | RLSD control line is ON |
● Off | Module is not in loopback or BERT | |
| ● Green | Local loopback is active, or BERT running with no errors |
| ✷ Blinking Yellow | Module is running a BERT with bit errors |
ALM | ● Red | BERT running with no pattern sync |
● Off | No alarm condition detected | |
| ● Yellow | Remote alarm condition detected |
| ● Red | Alarm condition detected locally |
V.35 Port |
|
|
|
Circuit No. | Circuit Name | To/From DCE | Pinout (A/B) |
102 | Signal Ground |
| B |
103 | Transmit Data | To | P/S |
104 | Receive Data | From | R/T |
105 | Request To Send | To | C |
Provisioning |
| Options | Default |
|
|
|
|
Unit Options |
|
|
|
|
| All Idle | |
Local Management |
| Disabled, Enabled | Enabled |
LT Mode Clk Source |
| Internal Clock | Internal Clock |
|
| Nx64 ETC |
|
|
| G.703 RX Clock |
|
NTU Auto Provisioning |
| Disabled, Enabled | Disabled |
External Port Alarms |
| Disabled, Enabled | Enabled |
Line Card Service State |
| In Service | Out of Service - Unassigned |
| Out of Service - Maintenance |
| |
| Out of Service - Unassigned |
| |
G.703 Port Service State |
| In Service | Out of Service - Unassigned |
| Out of Service - Maintenance |
| |
| Out of Service - Unassigned |
| |
Nx64K Port Service State |
| In Service | Out of Service - Unassigned |
| Out of Service - Maintenance |
| |
| Out of Service - Unassigned |
| |
SHDSL Options |
|
|
|
Rate (Kbps) | Enter a new value for N from 3 to 36, | 2056 (N=32) | |
| where Rate(Kbps)=(N x 64) + 8: |
| |
SNR Margin Alarm Threshold(dB) | Disabled, Enabled | Disabled | |
Loop Attenuation Alarm Threshold (dB) | Disabled, Enabled | Disabled | |
Test Options |
|
|
|
Loopback Timeout(Min) |
| Disabled, Enabled | Disabled |
BERT Test Pattern |
| All Zeros | |
|
| All Ones |
|
|
|
| |
|
|
|
G.703
SHDSL
106 | Clear To Send | From | D |
BERT Test Pattern Polarity | Normal, Inverted | Normal |
G.703
Nx64K
TX
RTS
RLSD
TST
ALM
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
107 | Data Set Ready | From | E |
108/2 | Data Terminal Ready | To | H |
109 | Received Line Signal Detect | From | F |
113 | Transmit Signal Element Timing | To | U/W |
114 | Transmit Signal Element Timing | From | Y/AA |
115 | Receive Signal Element Timing | From | V/X |
140 | Remote Loopback | To | N |
141 | Local Loopback | To | L |
142 | Test Indicator | From | NN |
The G.703 signal is transmitted to the network either via the Total Access 3000 backplane connectors or the two BNC connectors mounted on the faceplate. The G.703 signal and the SHDSL signal use the following backplane amphenol connector Pairs:
■SHDSL - Pair 2■G.703 Tx - Pair 8
■G.703 Rx- Pair 7
Nx64K | Disabled, Enabled | Disabled |
This product is intended for installation in restricted access locations only and in equipment with a Type “B” or “E” enclosure.
Code | Input | Output |
Power Code (PC) | F | C |
Telecommunication Code (TC) | – | X |
Installation Code (IC) | A | – |
HANDLING PRECAUTIONS REQUIRED. | ■ For a complete Installation and Maintenance faxback: (877) |
|