Association

The ZRW113 supports the Association command.

The ZRW113 can be set to control other Z-Wave devices. You can turn on and off, and even dim other Z-Wave devices once they are “associated” into either of 2 groups of the ZRW113.

Each group is turned on, off or dimmed by tapping or holding the switch a differing amount of times.

If you associate Z-Wave devices into Group 2, you can turn those devices on and off by tapping the switch on or off twice. You can brighten or dim devices by tapping the switch on or off once and then holding the switch. The load attached to the ZRW113 is not affected.

If you associate Z-Wave devices into Group 3, you can turn those devices on or off by tapping the switch on or off three times. You can brighten or dim devices by tapping the switch on or off twice and then holding the switch. The load attached to the ZRW113 is not affected.

You can associate up to 5 Z-Wave devices into each of these groups.

For instructions on how to “associate” a Z-Wave device into one of these groups, refer to your wireless controller instructions. (If you are using the ZTH100 controller, refer to the Setup Menu, Association section).

A NOTE ABOUT DIMMING: If you combine Z-Wave enabled dimmers and other types of Z-Wave devices in a group, place a Z-Wave enabled dimmer into the empty group 1st to ensure that the dimming operates correctly.

Configuration

The ZRW113 supports the Configuration command.

The ZRW113 can be configured to operate slightly differently than how it works when you first install it. Using the Configuration command you can configure the following:

You can use a ZTH100 to send Configuration commands. (Refer to the Setup Menu, Configuration section)

Set Ignore Start Level Bit When Transmitting Dim Commands

The ZRW113 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded in it. A dimmer receiving this command will start dimming from that start level if this bit is set to 0. If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level.

Parameter No: 1

Length: 1 Byte

Valid Values = 0 or 1 (default 1) Night Light

The LED on the ZRW113 will by default, turn ON when the load attached is turned ON. To make the LED turn ON when the load attached is turned OFF instead, set parameter 3 to a value of 1.

Parameter No: 3

Length: 1 Byte

Valid Values = 0 or 1 (default 0)

Invert Switch

To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1.

Parameter No: 4

Length: 1 Byte

Valid Values = 0 or 1 (default 0) LED Transmission Indication

The ZRW113 will flicker its LED when it is transmitting to any of its 2 groups. This flickering can be set to not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second when it begins transmitting (set to 2). By default, the ZRW113 is set to flicker for only 1 second.

Parameter 19

Length: 1 Byte

Valid Values = 0 , 1, 2 (default 2)

Each Configuration Parameter can be set to its default setting by setting the default bit in the Configuration Set command. See your controller’s instructions on how to do this (and if it supports it).

All Configuration commands will be reset to their default state when the ZRW113 is RESET from the Z-Wave system.

HomePro

0766-01

Z-Wave ZRW 113 Instructions, Series 200, Release 2.2

by ADVANCED CONTROL TECHNOLOGIES, INC.

3

P/D 011008

Page 3