INTRAC 204 Antenna Control Unit
SPECIFICATIONS
|
| SPECIFICATIONS |
| |
Operational modes | Standby | Manual (Jog) | Search | Remote Control |
| Auto (INTRAC) | Go To (Position Designate) |
|
|
Tracking Accuracy | Typically better than 0.1dB RMS signal degradation after tracking for 24 hours (with tracking signal), for orbit | |||
| inclinations up to 10° |
|
|
|
Prediction Accuracy | Typically better than 0.1dB RMS signal degradation over 72 hours (after loss of tracking signal), for orbit | |||
| inclinations up to 10° |
|
|
|
Backup | Model data is stored in EEPROM and the real time clock supported by battery backup against power failure | |||
Configuration Memory | Configuration data is stored in EEPROM |
|
| |
Tracking Signal | May be derived from an external tracking receiver or optionally from the integral | |||
External Tracking Signal | Voltage varying directly with received signal strength (in dB). |
|
| |
| Sensitivity 0.1V / dB to 1.0V / dB |
|
| |
| Offset + / - 10 volts max |
|
|
|
| Lost Lock input, contact closure when tracking signal is lost. |
|
| |
Display | 2 line LCD display giving the areas of information: |
|
| |
| Azimuth angle | Signal strength |
| Elevation angle |
| Diagnostics | Polarization angle |
|
|
| Mode of operation | Operational menus |
|
|
Drive Outputs | 36VDC, up to 8A for direct drive of DC actuator motors |
|
| |
Limit Switches | Limit switch inputs for elevation, azimuth and polarization. Contacts normally closed | |||
Position Transducers | Inputs for standard resolver position transducers |
|
| |
OPTIONS |
|
|
|
|
Internal |
|
|
|
|
| This option accepts an | |||
| The signal voltage and lock lost indicators are generated internally. The need for an external beacon | |||
| receiver is eliminated. |
|
| |
Remote Control Terminal | IBM PC compatible software is available to provide a remote | control terminal function. The terminal | ||
| monitors and controls the INTRAC via the standard serial remote control port and provides facilities for | |||
| managing and storing multiple orbit models. Alarm information is still available at the front panel. | |||
Polarisation Option | Option to accept a polarization position transducer and to drive a 36VDC polarization motor. |
PHYSICAL
Temperature
Range
Humidity
Altitude
Input Power
Dimensions
Mounting
Weight
0 to 50oC - Operating
5% to 95% RH non condensing - Operating
0% to 99% RH non condensing - Non Operating (storage)
10,000 feet max
110 or 230V, single phase, 50/60Hz, 50W
483mm (W) x 133mm (H) x 443mm (D).
19" rack mounting unit, 2U high.
8 kg
NORTH AMERICA | EUROPE | SOUTH AMERICA | An ISO 9001 : 2008 Company |
USA | UNITED KINGDOM | BRAZIL |
|
Tel: + 1 703 | Tel: +44 1480 357 600 | Tel: +55 11 3054 5701 |
|
Fax: +1 703 | Fax: +44 1480 357 601 | Fax: +55 11 5041 4026 |
|
info.usa@advantechwireless.com | info.uk@advantechwireless.com | info.brazil@advantechwireless.com |
|
CANADA | RUSSIA & CIS |
|
|
Tel: +1 514 | Tel: +7 495 967 1859 |
|
|
Fax: +1 514 | Fax: +7 495 967 30 24 |
| Ref.: |
info.canada@advantechwireless.com | info.russia@advantechwireless.com |
| |
|
|
| |
www.advantechwireless.com |
| Specifications are subject to change without notice |