2.2 DIP-Switch

The DIP-Switch is used to configure operation mode for LFP (Link Fault Pass- Through) and operation mode for UTP/Fiber port. The default value of DIP-switch is OFF.

Table 2.2: EKI-2741series DIP-Switch Definition

S/W No

Status

Description

1

ON

Enables Port/Power Alarm

 

 

OFF

Disable Port/Power Alarm

 

 

 

 

2

ON

Enables LFP

 

 

OFF

Disables LFP

 

 

 

 

Link Fault Pass-Through(DIP-Switch 2): When LFP is enabled, it allows UTP link failures to be reported to the fiber side and also allows Fiber link failures to be reported to the UTP side. Therefore, a link loss forwarding feature is provided in both UTP and Fiber side.

Note

Please don’t change the DIP-switch setting when UTP or fiber port is

 

transmitting or receiving data. It may cause some data error. Besides, if you

 

change the DIP-switch setting, please power off the converter and power on

 

again to make the setting effective.