26What to do if…

7.Screw the hose back to the machine and

make sure the connection is tight.

8. Turn on the water tap.

Frost precautions

If the machine is installed in a place where the temperature could drop below 0°C, proceed as follows:

1.close the water tap and unscrew the water inlet hose from the tap;

2.place the end of the emergency emptying hose and that of the inlet hose in a bowl placed on the floor and let water drain out;

3.screw the water inlet hose back on and reposition the emergency emptying hose after

having put the cap on again.

By doing this, any water remaining in the machine is removed, avoiding ice forming and consequently damage to the appliance.

When you use the machine again, make sure that the ambient temperature is above 0°C.

Emergency emptying out

If the water is not discharged, proceed as follows to empty out the machine:

1.pull out the plug from the power socket;

2.close the water tap;

3.if necessary, wait until the water has cooled down;

4.open the pump door;

5.place a bowl on the floor and place the end of the emergency emptying hose into the bowl. Remove its cap. The water should drain by gravity into the bowl. When the bowl is full, put the cap back on the hose. Empty the bowl. Repeat the procedure until water stops flowing out;

6.clean the pump if necessary as previously described;

7.replace the emergency emptying hose in its seat after having plugged it;

8.screw the pump again and close the door.

What to do if…

Certain problems are due to lack of simple maintenance or oversights, which can be solved easily without calling out an engineer. Before contacting your local Service Centre, please carry out the checks listed below.

Page 26
Image 26
AEG 74950A user manual What to do if…, Frost precautions, Emergency emptying out