AEG 8259 S, 825 D manual I n s t a l l a t i o n, Safety warnings for kitchen unit installer

Models: 825 D 8259 S

1 17
Download 17 pages 22.95 Kb
Page 8
Image 8
I n s t a l l a t i o n

I n s t a l l a t i o n

Safety warnings for kitchen unit installer

When used as an extractor unit, the hood must be fitted with a 120mm diameter hose.

If the fumes must be forced out through the wall, you must obtain a MKZ sizable wall exhaust pipe (with

external exhaust and air intake), E-Nr.- 610 899 004 (Ø 120 mm) which is one of our optional parts.

● When installing the hood, make

sure you

respect

the

following

minimum

distance

from

the

top edge

of the cooking hob/ring surfaces:

 

 

 

electric

cookers

600

mm

 

 

gas

cookers

 

650

mm

 

 

coal

and

oil

cookers

700

mm

min.

The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no cir- cumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.

It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct.

The air outlet installation must comply with the regulations laid down by the relevant authorities.

When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole .

National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.

The national decree on fuel-burning systems specifies a maximum depression of 0.04 bar in such rooms.