6Installation instructions

Make electrical mains terminal free of voltage.

Install correctly to give shock protection.

Loose and incorrect plug and socket connections can make the terminal become too hot.

A qualified electrician must install the connections in the clamps correctly.

Use a strain relief clamp on cable.

Use the correct mains cable of type H05BB-F Tmax 90°C (or higher) for a single phase or two phase connection.

Replace the damaged mains cable with a special cable (type H05BB-F Tmax 90°C; or higher). Speak your local Service Centre.

The appliance must have the electrical installation which lets you disconnect the appliance from the mains at all poles with a contact opening width of minimum 3 mm.

You must have correct devices to isolate: line protecting cut-outs, fuses (screw type fuses removed from the holder), earth leakage trips and contactors.

Assembly

 

min.

 

500mm

min.

min.

50mm

50mm

 

min.

 

5mm

R5mm

600mm

=

490+1mm 560+1mm

 

=

min. 25 mm min.

min. 5 mm 20 mm

min. 38 mm

min. 5 mm