J. TO REMOVE ELECTRODES (LHR, RHR, RHF BURNERS)
1. Isolate from electric supply.
2. Proceed as ‘TO REMOVE THE HOTPLATE’.
3. Proceed as ‘TO REMOVE SPARK GENERATOR’disconnect the appropriate electrode
lead.
4. Withdraw clip securing electrode to burner and withdraw lead and electrode (See Fig. 27).
5. Re-assemble in reverse order.
K. TO REMOVE ELECTRODE (LHF BURNER)
1. Isolate from electrical supply.
2. Proceed as ‘TO REMOVE HOTPLATE’.
3. Proceed as ‘TO REMOVE SPARK GENERATOR’.
4. Disconnect the left hand burner pipe (13mm) and the inner burner pipe (13mm) using the
special spanner.
5. Remove the burner and burner fixing plate, by unscrewing the 4 screws holding the burner
mounting plate in place.
6. Turn burner over and remove electrode fixing clip. Withdraw electrode through top of
burner checking on route of lead.
7. Re-assemble in reverse order, re-routing lead along the same path.
50
DESN 513541
DESN 513530
Fig. 27
Fig. 28