36 Getting Started Chapter 1
Example: Differential
Divider or Filter
Configuration
Any channel can be configured as a differential divider (with op tional filter)
connected to the normally open contact of the Form C relay. The d ifferential
divider requires that two channels be used.
Figure 1-23 shows channel 24 and 25 in this configuration wi th the optional
filter. For resistors R24 and R25, add a cross-channel capacito r for a
differential filter or add a cross-channel resistor for a differential d ivider.
No configuration jumpers are required.
Figure 1-23. Example: Differential Divider or Filter Configuration
RP24-31
User Supplied Resistor Packs (SIP) Locations
and associated pullup voltage (for optional standup resistors)
Solder Holes
Channel Resistor
Solder Holes
Channel Capacitor
Jumpers
Configuration
Channel
Channel
Number
V0-7
RP0-7
RP8-15
V8-15
RP16-23
V24-31
V16-23
Module
Terminal
To
Wiring
User
R or C
CH 24
CH 25
NO
NC
COM
NC
NO
NO
COM
NC
COM
NC
NO
COM
R24
Cross-Channel
NC
NO
COM NC
NO
COM
R25
Add Resistor
Differential Divider:
Add Capacitor
Differential filter:
RC
MODULE
TERMINAL MODULE
SWITCH
Channel 24