6 - Language Dictionary
68
Password Protection
An application program must provide a password to open a connection to a server. As shipped from the
factory, the Agilent MCCD is not password protected. You may set an Agilent MCCD server password
during the installation procedure using the Agilent MCCD Configuration Screens.
API Function Summary
cfAbort aborts a forming sequence
cfCal begins a full calibration (mainframe and card)
cfCalStandard begins a standard calibration (mainframe)
cfCalTransfer begins a transfer calibration (card)
cfClose closes a server connection
cfDeleteGroup deletes a group from the Agilent MCCD
cfGetCellStatus returns the status of an individual cell
cfGetCellStatusString returns detailed information for a failed cell
cfGetCurrent returns the current setting programmed by cfSetCurrent
cfGetGroups Returns information about all defined groups
cfGetDigitalConfig returns the setting of an individual digital I/O port
cfGetDigitalPort reads a data word from the digital I/O port
cfGetInstIdentify returns a description of the instrument
cfGetInstStatus returns the instrument status
cfGetMeasLogInterval returns the criteria that determines when data is logged
cfGetOutputConfig returns the configuration of an output
cfGetOutputProbeTest returns the output probe resistance limit
cfGetOutputState returns the output state of the Agilent MCCD
cfGetRunState returns the present instrument run state
cfGetSense returns the setting of the remote or local sense
cfGetSenseProbeTest returns the settings of the sense probe test
cfGetSeqStep returns the parameters for a sequence step number
cfGetSeqTest returns the parameters of one of the sequence tests
cfGetSeqTestAnd returns the parameters of multiple tests combined with the AND function
cfGetSeqTime returns the elapsed time since the sequence was triggered
cfGetSerialConfig returns the communication parameters of a serial port
cfGetSerialStatus returns the status of a serial port
cfGetStepNumber returns a cell’s present sequence step and the time since the step started
cfGetShutdownDelay returns the delay value set by cfSetShutdownDelay
cfGetShutdownMode returns the shut down mode setting
cfGetTrigSource returns the selected trigger source
cfGetUserIdentify returns the Name, Location, and Description information
cfGetVoltage returns the voltage setting programmed by cfSetVoltage
cfInitiate initiates a forming sequence
cfMeasACResistance measures the ac resistance of a cell or all cells
cfMeasCapacityAS measures accumulated ampere-hour capacity of a cell in its present step
cfMeasCapacityWS measures accumulated watt-hour capacity of a cell in its present step
cfMeasCurrent measures the current of a cell or all cells