32
12.7. AI-900CO Outside Line Interface Card Connection
12.7.1. Outside line and AI-900CO connection
The AI-900CO can be interfaced with up to 2 outside lines. Using DTMF tone dialing, it is compatible with both
loop and ground start systems.
[Connection]
Connect as shown below.
Outside line and AI-900CO connection
1 twisted pair cable
1 twisted pair cable
AI-900CO
CN1
CN2
CN3
CN4
GND *1
GND
Front view of
the circuit board
Outside line
Line 1
GND *1
GND
Outside line
Line 2
Lightening
protector *2
Lightening
protector *2
U.S.O.C. *3
RJ11C or W
C/O Line 1
(or PBX
Extension)
C/O Line 2
(or PBX
Extension)
*1Ground this terminal only when using ground start system.
*2Install a protector if not yet installed by the telephone company.
*3This terminal must be installed by the telephone company.