Aiphone ie-ssv manual Wiring Diagrams, IE Series Chime Tone Door Answering System

Models: ie-ssv

1 4
Download 4 pages 3 Kb
Page 2
Image 2
WIRING DIAGRAMS:

WIRING DIAGRAMS:

AX System with AX-8M master and pinhole camera being viewed on standard monitor:

Splice 2 wires of IE-SSV to Cat5E wire as shown: See wiring diagram below.

 

Standard CCTV

IE-SSV

Monitor

Red

 

Blk

 

 

Video output to monitor

 

or CCTV system (Yellow)

 

12V DC power input for camera

 

(Red - Must use supplied transformer)

AX-084C pictured

AX-8M

 

IE-SSV

TIA/EIA 568B Standard:

Red

Connect 3/6 pair (green) to “Red”

Connect 7/8 pair (brown) to “Black”

Blk

Illustration of converting from 2-conductor to CAT-5e cable.

CAT5e

Homerun each sub to

AX-084C, AX-248C, or

 

AX-320C CEU.

Use your preferred method for splicing cables to interface a standard 2-conductor cable run from the door station to the CAT-5 cable and RJ45 jack, required for connection to the CEU.

IE Series Chime Tone Door Answering System:

IE-SSV

Red

Blk

Video output to monitor or CCTV system (Yellow)

12V DC power input for camera

(Red - Must use supplied transformer)

IE-1AD

IE-1GD

IE-2AD

D1

E1

L

LPower Supply

+

+

-

 

 

-

 

 

Page 2

Page 2
Image 2
Aiphone ie-ssv manual Wiring Diagrams, IE Series Chime Tone Door Answering System