WIRING DIAGRAM: |
NO
COM
NC
Board on back of unit
N/O Dry Contact See wiring below
0.5 Amp
RELAY BOARD WIRING AND SETTINGS:
Configuration Switch
See Settings to right
| OFF | ON |
|
| 1 |
Relay 1 Output | NO | 2 |
C | 34 | |
N/O, COM, N/C | NC |
|
Relay 2 Output | NO |
|
C |
| |
N/O, COM, N/C | NC |
|
*Relay 2 External Reset Connect to N/O dry switch
Default Configuration when shipped
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication. Relay 2 triggers on emergency call and remains on during communication.
|
|
|
|
|
|
| ON |
| Trigger Source | RY1 Triggered? | RY1 Remains ON | RY2 Triggered? | RY2 Remains ON | RY2 Requires |
|
|
|
|
|
| |||||||||
1 |
|
|
|
|
|
|
|
| During Talking? | During Talking? | Reset? | |||
2 |
|
|
|
|
|
|
|
| Normal Call | YES | YES | NO | N/A | N/A |
3 |
|
|
|
|
|
|
|
| Emergency Call | YES | YES | YES | YES | NO |
4 |
|
|
|
|
|
|
|
| Talking | YES | YES | NO | N/A | N/A |
|
|
|
|
|
|
|
|
| Door Release | NO | N/A | NO | N/A | N/A |
Optional Configuration
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication. Relay 2 triggers on an emergency call and remains on during communication. Relay 2 requires reset.
|
|
|
|
|
|
| ON |
| Trigger Source | RY1 Triggered? | RY1 Remains ON | RY2 Triggered? | RY2 Remains ON | RY2 Requires |
|
|
|
|
|
| |||||||||
1 |
|
|
|
|
|
|
|
| During Talking? | During Talking? | Reset? | |||
2 |
|
|
|
|
|
|
|
| Normal Call | YES | YES | NO | N/A | N/A |
3 |
|
|
|
|
|
|
|
| Emergency Call | YES | YES | YES | YES | YES* |
4 |
|
|
|
|
|
|
|
| Talking | YES | YES | NO | N/A | N/A |
|
|
|
|
|
|
|
|
| Door Release | NO | N/A | NO | N/A | N/A |
Contact Technical Support if additional switch configurations are required.
SPECIFICATIONS:
Camera unit: | CMOS camera |
Scanning line: | 525 lines |
Min. illumination: | 5 Lux at 1’6” |
Terminations: | RJ45 jack for audio/video |
| Screw terminals for door release and relay outputs |
Relay rating: | 24V AC/DC 0.5A on Door station, 24V AC/DC 1.0A on relay board |
Operating Temp: | 14° ~ 140°F / |
Wiring Distance: | 980’ with Cat5e/6 cable |
Dimensions: | |
| FCC WARNING: |
| This device complies with Part 15 of the FCC rules. |
Operation is subject to the following two conditions:
(1)This device may not cause harmful interference.
(2)This device must accept any interference that may cause undesired operation.
•For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable.
•Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Aiphone Corporation | TOLL FREE TECHNICAL SUPPORT: |
1700 130th AVE NE * Bellevue, WA 98005 | |
Ph: (800) | (800) |
tech@aiphone.com |
Pg. 2