Special
Order
Products
LS-NVP (-W)
Vandal Proof Sub Station for
SBX-NVP
Surface Mount Box for LS-NVP
- INSTRUCTIONS -
The
WIRING DIAGRAM:
|
| |||
| Master |
| ||
|
|
| ||
| 1 | Red | ||
|
| |||
| 2 |
| Red | |
| ~ |
|
| |
10 | Blk* |
| ||
E | Blk* | |||
+ | ||||
+ | Grn |
| ||
- | - | Grn |
WIRING DIAGRAM:
MasterLS-NVP
1 | Red |
E | Blk |
| Grn |
~ |
|
Switch on PC board:
Leave in the LOWER position (set from factory), for use with LEM,
*In single master system, 2 conductors homerun can be used with the BLK and GRN wires tied together and "E" and
Switch on PC board:
Move to the UPPER position for use with
Tie Blk and Grn wires together for all installations with the
| 10 |
| Red |
| ||||||
| E |
|
|
| Blk |
|
|
| ||
|
|
|
|
|
| |||||
SPECIFICATIONS: |
| Grn |
|
|
|
| ||||
|
|
|
| |||||||
|
|
|
|
|
|
|
| |||
Power Source: |
|
| Supplied by master station |
| ||||||
Speaker: |
|
| 20 ohms, 3" diameter, water proof and puncture resistant, 2.5 oz. ceramic magnet |
| ||||||
Call Button: |
|
| Single pole, single throw (SPST), normally open (N/O) |
| ||||||
Faceplate: | 11 gauge carbon steel with |
| ||||||||
Communication: |
|
| Hands free at sub. Master is |
| ||||||
Mounting Hardware: |
|
| Tamper proof screws |
| ||||||
Terminations: |
|
|
| |||||||
Wiring: |
|
| RED to # terminal, BLK to "E" (Common) terminal, GRN to |
| ||||||
|
|
| Shielded cable is recommended. |
| ||||||
|
|
| Use Aiphone #822202 or #821802 for homerun wiring, #822206 for up to 4 stations |
| ||||||
|
|
| on each run, or #822210 for up to 8 stations on each run. |
| ||||||
Wiring Distance: |
|
| 650' with 22AWG; 1,600' with 18AWG. |
| ||||||
Dimensions (H x W x D): |
| |||||||||
Aiphone Communication Systems | TOLL FREE TECHNICAL SUPPORT: |
| ||||||||
1700 130th Ave. N.E. |
| (800) |
|
|
|
|
|
| ||
Bellevue, WA 98005 |
| TOLL FREE FAX LINE: |
| |||||||
(425) |
|
|
| (800) |
|
|
|
|
| |
FAX (425) |
|
|
| 0698bkjd |