ARCHITECT/ENGINEERS SPECIFICATIONS: The intercom system shall be of an open voice
type with simplex communication. Capacity shall be one remote station and one master station, available as a packaged set
Master station shall be equipped with a TALK button, OFF button for standby mode, and door release button. When TALK button is pressed, voice is transmitted to the remote station. Person at the remote station shall speak hands free. Door release button (key symbol) shall allow for activation of door strike or maglock. Door release button shall be supplied with “normally open” contacts, and shall be
Door station shall be equipped with button to signal master station. Unit shall be weather resistant, made for outdoor installation.
Voice volume control on the master station shall control transmit and receive volume, and a call tone volume control shall be located beneath the operation plate. An incoming call shall be annunciated by a momentary electronic call tone. When using the dual master
Master station shall wall mount on a
Wiring shall be two conductors with an overall shield inside a single jacket. Wiring between LEM- 1DL/C master stations shall be three conductors with an overall shield. Door strike shall be wired with a separately jacketed two conductor wire, non- shielded, from the master station(s) to the strike and power source for the strike.
Product shall be manufactured by Aiphone or approved equal. Manufacturer must have earned ISO 9001 certification for quality standards.
SPECIFICATIONS: |
|
Power source: | |
| Use |
| source within the specified voltage range. |
Current Consumption: | Max. 4W (AC 16V). Max. 200mA (DC 24V). |
Output: | 100mW @ 20 ohms |
Communication: | |
| master station. |
| Hands free at remote station. |
Capacity: | |
| |
Wiring: | Shielded wire is recommended for |
| communication. |
| 2 conductors from master to remote |
| 3 conductors beteen |
| 2 conductors from master to power source |
Door Strike Wiring: | 2 conductors from master to door strike |
| (in a separate jacketed cable from the |
| communication wiring) |
Wiring Distance: | 650’ w/22AWG; 1570’ w/18AWG |
Door release |
|
button contact: | 30V, AC or DC, 1A |
Speaker sensitivity: | 40dB |
Total Harmonic |
|
Distortion: | Less than 5% at rated output power |
Signal to Noise Ratio: | 60dB |
Frequency Response: | |
Dimensions | |
(H x W x D): | |
| |
|
WALL MOUNTING:
Intercom Solutions For
Communications and Security
AIP 90300 0902
Aiphone Communication Systems • 1700 130th Ave. NE • Bellevue, WA 98005 (425)