SPECIFICATIONS:
Power source: 12-16V AC or 12-24V DC
Use PT-1210N AC Transformer or power
source within the specified voltage range.
Current Consumption:
Max. 4W (AC 16V). Max. 200mA (DC 24V).
Output: 100mW @ 20 ohms
Communication: Press-to-talk, release-to-listen at
master station.
Hands free at remote station.
Capacity: LEM-1DL: 1 master, 1 remote
LEM-1DL/C: 2 masters, 1 remote
Wiring:

Shielded wire is recommended for

communication.

2 conductors from master to remote
3 conductors beteen LEM-1DL/C masters
2 conductors from master to power source
Door Strike Wiring: 2 conductors from master to door strike

(in a separate jacketed cable from the

communication wiring)

Wiring Distance: 650’ w/22AWG; 1570’ w/18AWG
Door release
button contact: 30V, AC or DC, 1A
Speaker sensitivity: 40dB
Total Harmonic
Distortion: Less than 5% at rated output power
Signal to Noise Ratio:
60dB
Frequency Response:
-3dB, 770-6800Hz.
Dimensions LEM-1DL, LEM-1DL/C:
(H x W x D): 7-1/16” x 5-5/8” x 2-1/8”
LE-D:
4-3/4” x 3-1/2” x 1-1/8”
ARCHITECT/ENGINEERS SPECIFICATIONS:
The intercom system shall be of an open voice
type with simplex communication. Capacity shall
be one remote station and one master station,
available as a packaged set (LEM-1DLS). A dual
master system shall be available (two LEM-1DL/C
masters plus door station and two transformers).
Master station shall control communication, with
hands free reply from the remote station.
Master station shall be equipped with a TALK
button, OFF button for standby mode, and door
release button. When TALK button is pressed, voice
is transmitted to the remote station. Person at the
remote station shall speak hands free. Door release
button (key symbol) shall allow for activation of door
strike or maglock. Door release button shall be
supplied with “normally open” contacts, and shall
be field-modifiable for “normally closed” contacts.
Door station shall be equipped with button to
signal master station. Unit shall be weather resistant,
made for outdoor installation.
Voice volume control on the master station shall
control transmit and receive volume, and a call tone
volume control shall be located beneath the operation
plate. An incoming call shall be annunciated by a
momentary electronic call tone. When using the
dual master LEM-1DL/C stations, the “Occupied”
LED shall light to indicate that the system is in use.
Master station shall wall mount on a 1-gang box
or ring, or be placed directly on a desk or counter.
Remote stations shall be available in the following
configurations: (1) weather resistant door stations
in surface or flush mount styles, mounted on or in
standard 1-gang or 2-gang boxes, (Model LE-D,
LE-DL, or LE-DA); or (2) vandal proof weather
resistant style (LS-NVP/B), mounted in a standard
3-gang masonry box, or with optional surface mount
box (SBX-NVP).
Wiring shall be two conductors with an overall
shield inside a single jacket. Wiring between LEM-
1DL/C master stations shall be three conductors with
an overall shield. Door strike shall be wired with a
separately jacketed two conductor wire, non-
shielded, from the master station(s) to the strike and
power source for the strike.
Product shall be manufactured by Aiphone or
approved equal. Manufacturer must have earned
ISO 9001 certification for quality standards.
WALL MOUNTING:
AIP 90300 0902
Intercom Solutions ForCommunications and Security
LEM-1DL
Aiphone Communication Systems • 1700 130th Ave. NE • Bellevue, WA 98005
(425) 455-0510 • FAX: (425) 455-0071 (800) 692-0200 • http://www.aiphone.com