2. MYW-P3L with MYH-CUB and LEF-C Audio:

2. MYW-P3L with MYH-CUB and LEF-C Audio:

 

 

(Audio system not shown)

MK-DAC*

 

MYW-P3L

A1

 

1A1

A2

MK-DAC*

1A2

 

Max. 500'

 

 

NOTE:

An audio intercom system is required for proper system operation. Select the appropriate system based on overall distance and communication requirements.

A1

A2

*VIDEO DOOR STATIONS:

Any Aiphone MK or MY Series video door station can be used:

-MK-DAC: Surface mount, black

-MK-DBC: Semi-flush mount, black

-MK-DGC: Semi-flush mount, metal cover

-MY-DGV: Semi-flush mount, vandal proof, stainless steel cover

-MK-DS/B: Surface mount, fixed camera

2A1

 

 

 

 

 

2A2

Wire #851602

MYW-BA-M

 

 

 

B1

 

 

A1

Wire #851602

MYH-CUB

B2

 

 

A2

 

 

 

 

 

 

 

B1

 

A1

 

 

 

B2

 

A2

 

 

 

 

 

B1

 

 

 

 

 

B2

U1

 

 

Brn

 

U1

U2

 

 

 

 

 

PS-1820UL

 

Org

PS-1820UL

U2

 

 

 

 

+

+

 

+

Do not connect + +

+

-

-

 

-

-

-

 

Wire #841806

 

Wire #841806

 

 

(+/- wires doubled)

 

(- wire doubled)

 

Total 1000'

SPECIFICATIONS:

 

Power Source:

18V DC. Use PS-18C for every three video units, including adaptor and monitors.

Current consumption:

250 mA (standby)

Scanning lines:

525 lines

Wiring distance:

MK Camera to MY-CU or MYW adaptor: Max. 330' with 18 AWG wire

 

MY-CU or MYW adaptor to MYW-BA-M: Max. 500' with Aiphone cables 841806 & 851602*

 

Max. distance from first to last MY monitor is 1000' with Aiphone cables 841806 & 851602*

 

* Total distance from first monitor/adaptor to farthest sub monitor cannot exceed 1000 feet.

Dimensions:

7-1/2"H x 3"W x 1-5/8"D

CAUTION

*Do not connect any AC wires to any terminal on any unit, as damage may occur. Connect only specified power source to + and - terminals.

*Do not install more or different power sources than specified for the system.

*Do not attempt to install or connect wires on the MY system while the system's power supply is plugged in.

*MY monitors and related equipment, unless specified as "weather resistant", are designed for indoor use only.

Video door stations (MK-DAC, MK-DBC, MK-DGC, MK-DS, MY-DGV) may be installed outdoors in a protected area. Do not expose any equipment directly to rain or extreme weather conditions.

IMPORTANT

*Any other manufacturer's products installed with the system (power supply, external device, etc.) are not covered under Aiphone's warranty.

*Do not mount Aiphone equipment in the following places, as it may cause the system to malfunction:

-High or extreme cold temperature areas: under direct sunlight, near equipment that varies in temperature, in front of air conditioner, inside a refrigerated area, etc.

-Places subject to moisture or humidity extremes.

-Places subject to environmental conditions, such as dust, oil, chemicals, salt, etc.

*All intercom and video units are electronic devices, which must not be subjected to water or any other liquid.

*Severe weather conditions, such as lightning storms, may cause damage to Aiphone equipment. We recommend that power surge protection be installed to minimize potential component level damage.

-Install the SA-1 surge arrestor to protect the power supply from a surge.

-Additional SA-1 surge arrestors should be installed on all communication lines (one SA-1 for every two connected to master.).

Aiphone Communication Systems

Toll Free Technical Support:

 

1700 130th Ave. N.E.

 

1-800-692-0200

Pg. 2

Bellevue, WA 98005

(425) 455-0510

FAX: 1-800-832-3765

MYW-BA-M Instr.

FAX (425) 455-0071

E-mail: tech-serv@aiphone.com

0703bkjs

Page 2
Image 2
Aiphone MYW-BA-M manual MYW-P3L with MYH-CUB and LEF-C Audio, Specifications, Toll Free Technical Support, Myw-Ba-M