DIMMENSIONS:
NE-DA
OPERATION:
1.To place a call, press call button on door station once. The
2.When the master station answers, a brief pretone will be heard. Speak into the door station hands free.
3.When the call is completed, the person at the master will press the OFF button and communication will be cut off. The person at the remote station does nothing.
4.If a corridor lamp is included, the lamp will be lit from the time the call is placed until it is answered.
5.If a relay is included at the remote station to provide an extra dry closure, the closure will be activated from the time the call is placed until it is answered. This extra contact can be wired to an alarm device, or to a CCTV switcher to activate a camera.
6.When using this system for camera
SPECIFICATIONS: |
|
Power Source: | Supplied by master station |
Speaker: | 20 ohms |
Call Annunciation: | Pressing call button at remote latches call at NEM master until answered |
Communication: | Hands free at sub. Master is |
Mounting: | Surface mount to |
Wiring: | 2 conductors homerun; or 1 common plus 1 individual per sub, looped through |
| each sub. Shielded cable is recommended. |
| Use Aiphone #822202 or #821802 for homerun wiring, #822206 for up to 5 |
| stations on each run, or #822210 for up to 9 stations on each run. |
Wiring Distance: | 420' with 22AWG; 1,000' with 18AWG. |
Dimensions: | |
|
|
Coil Rating: | 12V DC, supplied by H terminal of master |
Contact Rating: | 110V AC, 1A, or up to 24V DC, 1A |
Aiphone Communication Systems | TOLL FREE TECHNICAL SUPPORT: |
|
1700 130th Ave. N.E. | (800) |
|
Bellevue, WA 98005 | TOLL FREE FAX LINE: | Pg. 2 |
(425) | (800) | |
FAX (425) | 0103BKJS |