NHX
Nurse Center System
NH-1SA-AC NH-2SA-AC
Patient Stations
Single and Dual Patient Stations for All Call, and when sharing a common Corridor Lamp
- INSTRUCTIONS -
Some applications for Nurse Call systems require All Call. By including the
NOTE: An NHX system installed with an
WIRING DIAGRAM:
Two Patient Stations in one room sharing a bathroom and corridor lamp
11
12
Trunkage Line 13
Connection 14
Terminals
15
16
21
22
23
24
25
26
~
51
52
53
54
55
56
| |
A+ | + |
A- | - |
CN1: | CN1: |
Brn | Brn |
Red | Red |
Org | Org |
Yel | Yel |
Grn | Grn |
Blu | Blu |
Blk | Blk |
CN2: | CN2: |
Brn | Brn |
Red | Red |
Org | Org |
Yel | Yel |
Grn | Grn |
Blu | Blu |
Vio | Vio |
| * Bath call will annunciate on |
| one position at the master |
| station, according to which |
| patient station it is wired to. |
APPLICATION #1:
All Call feature added, where an announcement can be made from the master station to all patient stations simultaneously.
APPLICATION #2:
2 patient stations in a room with a common bathroom and one corridor lamp outside the room.
To NH-50AC
| ||
Brn | Corridor Lamp | |
Red | (Shared by both patient stations) | |
| ||
Org |
| |
|
| |
Yel | Bathroom Pullcord | |
Grn | (Wired to one station only) | |
|
|
Blu
B+ | + |
B- | - |
|
NOTES:
1.All Call requires one of the station buttons to be used for All Call. Therefore, the standard system can have up to 49 stations, and the expanded system can have up to 79 stations.
2.Only wiring concerning the
Aiphone Communication Systems | TOLL FREE TECHNICAL SUPPORT: |
|
1700 130th Ave. N.E. | (800) |
|
Bellevue, WA 98005 | TOLL FREE FAX LINE: |
|
(425) | (800) | |