Air-O-Swiss AOSU650 Further Information, RECOMMENDED TO CLEAN WITH EZCal, Troubleshooting

Models: AOSU650

1 2
Download 2 pages 17.55 Kb
Page 2
Image 2
FURTHER INFORMATION

FURTHER INFORMATION

RECOMMENDED TO CLEAN WITH EZCal

11

Switch off the appliance and unplug it from the socket before cleaning it. Clean the water tank and the base regularly. Use water only, no detergents.

12

30 min

140°F / 60°C

For best results use EZCal custom cleaning agent for AIR-O-SWISS products to remove deposits from the water base regularly. Do NOT run the unit when using EZCal. This can cause damage to the product and voids the warranty.

13

Do not submerge base in water! The cleaning indicator still appears on the display after cleaning. To reset hold down the On/Off Dial until the cleaning light disappears. Thoroughly rinse the base with tap water and make sure no EZCal residue remains in the base!

What is EZCal?

EZCal from AIR-O-SWISS is an easy and safe cleaning and descaling agent recommended for all humidifiers. It cleans mineral build-up in the water base.

There is a sample of EZCal included in the packaging of your humidifier!

Only use 1 packet for 32oz of water. Do not change the ratio. Thoroughly rinse the base with tap water and make sure no EZCal residue remains in the base. Instructions for use are on the packet. Please note: EZCal from AIR-O- SWISS is the only recommended cleaning and descaling solution. Do NOT use any other cleaning solutions since it can damage the product. Any use of cleaning solutions apart from EZCal will void the warranty.

EZCal descaling agent is available at selected retail stores and online at www.airoswiss.net.

TROUBLESHOOTING

White dust is emitted from the unit

White dust particles are minerals that are broken up in tiny pieces by the ultrasonic process. Solve the problem:

Soak the demineralization cartridge in a bowl of water for a minimum of 24 hours. If the cartridge is soaked in the water tank, the water in the tank and the base needs to be replaced before using the unit.

Exchange the demineralization cartridge after 1– 2 months when you use very hard water, for softer water after 2– 3 months. No matter how hard your water is, exchange the cartridge at the very latest after 6 months.

Don’t use water from a pre-installed water softener, or sodium instead of calcium will be emitted from the unit. Use distilled water instead and remove the demineralization cartridge.

For very hard water areas use only distilled water and remove the demineralization cartridge.

Use reverse-osmosis water (R-O water) instead of distilled water and remove the demineralization cartridge.

Cleaning light is on

Switch off the unit and unplug it. Empty the water in the base. Rinse the base with hot/clean water. Do not sub- merge the base! Visually inspect the base for dirt or mineral build up. If soft water is used, decalcifying the unit every 4 weeks with EZ Cal is suggested. If hard water is used the unit should be decalcified every 2 weeks. Do not forget to reset the cleaning light afterwards.

Reset cleaning light

The cleaning light does not automatically reset. Hold down the On/Off Dial (button A in instruction manual) until the light disappears. The light automatically comes on approx. 14 days after of plugging in the unit.

Use of distilled water

For best results with your ultrasonic humidifier use distilled water and remove the demineralization cartridge.

The hygrometer on unit reads a different humidity level than external hygrometer

Not all hygrometers are calibrated the same, and most are off by +/- 5%. Plus the humidity level is not the same in the whole room. The air circulation and temperature are diffe- rent in every corner of the room and may affect the humidity level. The unit should not be placed near a heat vent or a radiator as the heat will absorb all of the moisture.

Humidity level is not changing or does not reach the desired humidity level

If the water tank needs refilling more than once per day, the unit is working properly and the climatic condition in the

room has an influence on the humidity. Reasons for low humidity level:

air circulation is very high (air is fully exchanged several times per day – the humidifier needs to starts its work from scratch)

insulation of home (see air circulation)

open space with high ceilings (not only the footage of the room counts but also the height) – high-rise buildings require more humidification.

open windows – works similar to air circulation (if it is very cold outside don’t open the window more than 2 times per day for 3 minutes)

big difference between outside temperature and inside temperature – the colder the air the less moisture it is capable of holding. The more the air is heated up the lower the percentage of relative humidity (= the amount of water vapor in the air, compared to the amount the air could hold if it was totally saturated)

position of the unit – if it is placed close to a door, window or air vent. This increases the air circulation.

No mist / unit is not working / empty indicator keeps flashing

Fill up the water tank. Check to see if water is flowing through the demineralization cartridge (attached to the water tank cap). If the water tank is full but there is only little water in the base it indicates that the water is now flowing through the demineralization cartridge.

Wait for 15 minutes to allow the mist to come out of the unit.

If the unit is not working and the empty light is not flashing you might have set the desired humidity too low and the current humidity level in the room is higher. That is why the unit switches off automatically.

If the empty indicator keeps flashing and the tank is full, the water is not flowing through the cartridge. Exchange the cartridge or the granules in the cartridge after 2– 3 months, in areas with hard water exchange the cartridge after 1– 2 months. However the demineralization cartridge and or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore.

If the granules are new, see the following instructions: Make sure the cartridge and/or granules were soaked for 24 hours, dry granules take even longer for water to filter through the cartridge and into the base. Next, please remove a tablespoon of granules from the cartridge, and throw them away. When there are too many granules in the cartridge it does not allow water to flow from the tank to the base.

Unit is running intermittently

How long has it been since the contents of the cartridge were replaced? If 2-3 months have passed, it is time to replace the contents of the cartridge. However the demine- ralization cartridge and or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore.

If the contents of the cartridge were just replaced there are probably too many granules in the cartridge. Remove a tablespoon of granules from the cartridge.

Accessories

Do I need to keep any parts before I replace the demineralization cartridge?

Yes, always keep the water tank cap (this is the piece that attaches the demineralization cartridge to the water tank).

What is the Ionic Silver Stick (ISS) and how long is it good for?

The Ionic Silver Stick® (ISS) keeps the water free of micro- bial growth. The ISS uses the anti-microbial effect of silver to prevent the growth of microbes in the water base. It begins to function as soon as it comes into contact with water, even if the unit is switched off. The Ionic Silver Stick should be changed every year.

Placement of the Ionic Silver Stick

• Please see the quick set up guide for more instructions.

Replacement reminder

In each ISS box and on all the new products there is an ISS lifecycle indicator. Check the box of the month when starting to use the ISS and write the year on the line in- dicated. Exchange it after one year.

DO NOT DISCARD! Save for future reference.

Please read the manual or check our website www.airoswiss.net for further information.

Page 2
Image 2
Air-O-Swiss AOSU650 setup guide Further Information, RECOMMENDED TO CLEAN WITH EZCal, Troubleshooting, What is EZCal?