MODELO 4TM64A/9515A
MANTENIMIENTO | PARTES DE REPUESTO |
OPERATING INSTRUCTIONS & PARTS MANUAL
15 INCH DELUXE PIVOT FAN
ADVERTENCIA: DESCONECTE SIEMPRE EL CORDÓN ANTES DE INTENTAR REALIZAR CUALQUIER FUNCIÓN DE SERVICIO.
LIMPIEZA: Use un trapo y una solución de jabón suave, tal como detergente líquido para lavar trastes.
ADVERTENCIA: No use gasolina, bencina, diluyente de pintura ni limpiadores fuertes en aerosol, ya que éstos dañarán el ventilador.
ALMACENAMIENTO: Cuando no lo utilice, mantenga el aparato en
un lugar limpio y seco.
EL MOTOR HA SIDO PERMANENTEMENTE LUBRICADO.
| Ref. | No. de Parte | Descripción | Cant. |
|
|
|
|
|
|
|
| 1 | 2010788 | Cubierta del Motor (Trasera) | 1 |
|
2 | 2010793 | Botón del Interruptor | 1 |
| |
3 | 2090039 | Tornillo de #8 x 3/8 Tipo 25 PPH | 2 |
| |
4 | 2091108 | Tornillo de #8 x 3/4 Tipo AB HWH | 5 |
| |
5 | 2010786 | Rejilla Trasera | 1 |
| |
6 | 2010790 | Accesorio de Inserción de la Manija | 1 |
| |
7 | 2057067 | Interruptor | 1 |
| |
8 | 2090710 | Tornillo de #10 x 1/4 Tipo B | 1 |
| |
9 | 2050044 | Cordón Eléctrico | 1 |
| |
10 | 2010949 | Cubierta del Interruptor | 1 |
| |
11 | 2031229S | Conjunto del Motor | 1 |
|
15" (38.1 cm) MODEL 4TM64A/9515A
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT
DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY
WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
1 | 2 | 3 |
|
5
6
4
11
12 | 2010791 | Trinquete | 2 |
13 | 2010789 | Horquilla | 2 |
14 | 2091115 | Arandela Planas 1 x .205 x .062 | 2 |
15 | 2091116 | Tornillo de #8 x 5/8 Tipo 25 HWH | 2 |
|
|
|
|
16 | 2010794 | Hélice | 1 |
17 | 2010792 | Base | 1 |
18 | 2090038 | Tornillo de #8 x 9/16 Tipo 25 PPH | 2 |
19 | 2010414 | Pie | 4 |
20 | 2010785 | Rejilla Delantera | 1 |
21 | 2091109 | Tornillo de #6 x 3/4 Tipo 25 PPH | 2 |
8
7
9
10
21
DESCRIPTION
The AirKing 15" (38.1 cm) Deluxe Pivot Fan features 3 speed whisper- quiet operation, a
SPECIFICATIONS
must be inserted into a matching receptacle. Under no circum- stances must the grounding prong be cut off the plug. Where a two- prong wall receptacle is encountered, it must be replaced with a properly grounded
WARNING: USE OF A
3.Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed and of the proper gage and length. Never use a single extension cord to operate more than one fan.
4.Do not insert fingers or foreign objects into the fan. Do not block or tamper with the fan in any manner while it is in operation.
5.Unplug power cord before installing or servicing the fan.
WARNING: DO NOT DEPEND UPON THE
6.This fan is intended for general use ONLY. It must NOT be used in potentially dangerous locations such as flammable, explosive,
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE
16
Motor | 120V, 60 Hz | OPERATION |
Blade Diameter | 15" (38.1 cm) | 1. ADJUSTABLE TILT: To adjust direction of air, simply turn the |
13 | 20 |
|
|
| 14 |
|
| 15 |
14 | 15 | 12 |
| ||
|
|
13
12
17
19
18 19 18
Rev. A 6/99 (Motor) | 4 | 2084534 |
Speeds ................................ 3 |
|
|
|
| head of the fan. The 120° ratchet adjustment will securely snap | |||
Control ................................ Rotary Knob |
|
| and hold the fan in the desired position. | |||||
Air Flow Distribution ........... 120° Variable |
|
| 2. SPEED: Speed is controlled by three position rotary switch | |||||
|
| located on rear of fan. | ||||||
Approvals ............................ UL listed. Close mesh fan guard meets | ||||||||
3. POWER SUPPLY CORD: Plug power supply cord into a wall | ||||||||
|
| OSHA requirements. | ||||||
|
| outlet (AC 120 volts, 60 Hz). | ||||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| THE RACHET ASSEMBLY ON THE 15" DELUXE PIVOT FAN IS | |
| MODEL | 4TM64A/9515A |
|
| ||||
| SPEED | HIGH | MED |
| LOW |
| DESIGNED FOR POSITIVE LOCK POSITIONING. THEREFORE | |
|
|
| WHEN ADJUSTING THE FAN ANGLE A LOUD CLICKING SOUND | |||||
| CFM | 3285 | 2830 |
| 2210 |
| ||
|
|
| IS NORMAL. | |||||
| M3/s | 1.55 | 1.34 |
| 1.04 |
| ||
|
|
| MAINTENANCE | |||||
| RPM | 1220 | 1050 |
| 750 |
| ||
|
|
|
|
|
|
| WARNING: ALWAYS UNPLUG THE CORD BEFORE SERVICING. | |
| Amps | 1.10 | .80 |
| 0.62 |
| ||
| Watts | 115 | 95 |
| 75 |
| CLEANING: Use a soft cloth and a mild soap solution such as liquid | |
|
|
|
|
|
|
| dish washing detergent. | |
| dB A | 55 | 50 |
| 44 |
| ||
|
|
|
|
|
|
| CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners, | |
GENERAL SAFETY INFORMATION | etc. which will damage the fan. | |||||||
Dry all parts with a soft cloth completely before reconnecting to power | ||||||||
1. Make certain that the power source conforms to the electrical | supply. | |||||||
STORAGE: When not in use, keep unit in a clean dry place. | ||||||||
requirements of the fan. |
|
|
|
| ||||
|
|
|
| MOTOR IS PERMANENTLY LUBRICATED. | ||||
2. The power cord is equipped with a | ||||||||
| ||||||||
Rev. A 6/99 (Motor) |
|
|
| 1 | 2084534 |