IMPORTANT INSTRUCTIONS - OPERATING MANUAL

DESCRIPTION

1.For mounting listed Air King® circulators from the ceiling.

2.Distance mounted from the ceiling can be changed by using a length of 1-1/2" NPT pipe. Simply substitute your pipe for the provided pipe nipple.

CEILING MOUNT INSTALLATION

1.Locate the four hole pipe flange and securely mount to ceiling structure. Ensure ceiling structure can safely support the installed Fan.

2.Open one tube of Loctite #243 by snapping tube neck just below end cap. Be certain to follow all warnings noted on Loctite #243 tube. (Inset)

3.Apply (1) entire tube of Loctite #243 onto the first 2 threads on the end of the steel nipple.

4.Screw steel nipple, (or your longer pipe), into adapter. Steel nipple must be screwed in at least 4 full revolutions.

5.Tighten provided 1/4" set screw in the yoke adapter.

6.Screw the yoke with adapter assembly onto the pipe. This assembly must also be turned at least 4 full revolutions into the pipe flange.

7.Tighten the 1/4" set screw in the adapter down securely onto the steel nipple.

CAUTION: FAN IS HEAVY AND MAY REQUIRE TWO PEOPLE TO MOUNT.

8.Align Yoke with grill mounting threads. Loosely attach one Grill Knob and one Rubber Spacer to the Head Assembly. Attach the other Grill Knob and Rubber Spacer to the Head Assembly and FIRMLY tighten. Return to the first Grill Knob and FIRMLY tighten.

(Figure 1)

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

CAUTION: THE SECONDARY SUPPORT CABLE PROVIDED SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED OVERHEAD FOR ADDITIONAL SAFETY.

SECONDARY SUPPORT CABLE (Figure 2)

1.Loop one end of the Cable around the Large Diameter Wires of both the Front and Rear Circulator Guard.

2.Attach a Cable Clamp with the "U" on the tail sid eof the loop leaving a tail approximately 1 to 2 inces. Tighten Clamp Nuts. Make sure no part of the Cable interferes with the Blade.

3.Wrap the other end of the Cable around a secure building joist, truss, or othe support near the Fan. (Figure 3) Do not attach cable to I-Beam mount pipe. Take up all excess slack in the Cable.

CAUTION: Use only the mounting hardware which is recommended for use on this fan.

4.Attache the remaining Cable Clamp as indicated in Step 2. The excess tail should be trimmed to extend 1 to 2 inches past the Clamp.

5.Check the Assembly to assure the Blade is free of all obstructions.

CAUTION: Use of the secondary support cable does not guarantee protection against injury of persons. Mounting of both the circulator and cable could fail if subjected to abuse, neglect or improper installation.

Large

Secondary

Support

Guard Wires

Cable

 

Inset

Loctite #243

Application

Loctite #243

Floor Flange

Set Screw

Steel Nipple

 

Set Screw

 

Yoke

Rubber

 

Spacer

20" Only (9320)

Figure 2

Figure 3

 

OPERATING INSTRUCTIONS

1. To Operate: Plug cord into a grounded 120V, 60 Hz outlet. Select desired operating speed with pull cord on the rear of the motor:

First pull: High

Second pull: Medium

Third pull: Low

Fourth pull: OFF

WARNING:

This fan should be used only in a clean, dry environment.

Mounting of this product in any way other then specified in the instruction sheet

will null and void the manufacturer's warranty.

Floor Flange

InsetSet Screw

Steel Nipple

Set Screw

Loctite #243

Application

Loctite #243

18" Only (9718)

Rev. C 11/07

2

5084423

MAINTENANCE

WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING.

WARNING: DO NOT IMMERSE FAN IN WATER!

CLEANING: Use a soft cloth and mild soap solution such as liquid dish washing detergent. Dry all parts completely before reconnecting to power supply.

CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners, etc. as they will damage the Fan. NEVER use ALCO-

HOL OR SOLVENTS.

SERVICING: All other servicing, with the exception of general user maintenance, should be performed by an authorized service repre- sentative. Call 1-800-233-0268, Monday through Friday, between the hours of 8:00 a.m.and 5:00 p.m. Eastern for the location of your nearest service center.

LUBRICATION: Precision bearings are sealed at the factory for life and do not require further lubrication.

STORAGE: Store the Fan, with these instructions, in a clean and dry place.

Rev. C 11/07

3

5084423

Page 2
Image 2
Air King 9320, 9718 warranty Description, Ceiling Mount Installation, Operating Instructions, Maintenance, HOL or Solvents

9320, 9718 specifications

The Air King 9320 and 9718 are two highly regarded ventilation fans that combine functionality, efficiency, and durability, making them valuable additions to any home or commercial setting.

One of the standout features of the Air King 9320 is its powerful 1/6 horsepower motor, which provides substantial airflow while maintaining a low noise level. This makes it ideal for areas requiring effective ventilation without disturbing daily activities. With a CFM (cubic feet per minute) rating of 170, the 9320 efficiently removes smoke, odors, and moisture, ensuring a comfortable and healthy environment. The fan is designed for easy installation and comes with a durable, corrosion-resistant housing, making it suitable for use in bathrooms, kitchens, and laundry areas.

The Air King 9718, on the other hand, is known for its versatility and aesthetic design. It features a sleek, low-profile design that can blend seamlessly into any decor. The 9718 is equipped with a 1.5-sones noise level, making it one of the quieter models available. It boasts an impressive CFM rating of 80, effectively moving air while promoting energy efficiency. This model is ideal for smaller spaces, providing adequate ventilation without compromising style.

Both fans are constructed from high-quality materials, ensuring long-lasting performance. The use of durable plastic housing not only enhances longevity but also simplifies cleaning and maintenance. Furthermore, they are designed to be energy efficient, often meeting or exceeding ENERGY STAR guidelines, which translates to lower electricity bills and a reduced environmental footprint.

Installation is straightforward for both models, with a ceiling-mounting option included, making them suitable for a variety of applications. Whether installed in residential bathrooms or commercial kitchens, the Air King 9320 and 9718 serve to improve indoor air quality effectively.

In summary, the Air King 9320 and 9718 ventilation fans offer an exceptional combination of power, efficiency, and style. With features such as powerful yet quiet motors, efficient airflow rates, and durable construction, these fans stand out in any setting. They exemplify Air King’s commitment to creating high-quality ventilation solutions, making them top choices for those seeking reliability and performance.