Alcatel-Lucent 1511 BA manual Main Characteristics, Clock Synchronization, Mechanical Design

Models: 1511 BA

1 4
Download 4 pages 33.33 Kb
Page 4
Image 4
Main Characteristics

Automatic Protection Switch

The automatic protection switch (APS) enables route protection on E1 level. If used, the Alcatel-Lucent 1511 BA transmits data via two different E1 routes. At the receive side, data coming from the preferred route is used; if this route fails, data is taken from the other side.

Ethernet Switching

On an E1 trail across multiple Alcatel- Lucent 1511 BA multiplexers, a group of 64-kb timeslots (N: 1...31) is reserved to carry Ethernet frames. In each Alcatel- Lucent 1511 BA, one 10/100Base-T LAN board (LANtrib) can drop/insert its local Ethernet traffic onto these reserved timeslots. To connect multiple Ethernet- based end devices, the LANtrib offers five external RJ-45 interfaces. The LANtrib also switches LANs across mul- tiple and distinct Alcatel-Lucent 1511 BA multiplexers. Switching between the local five Ethernet ports runs at wire speed.

Technical Specifications

Main Characteristics

Compliant with all relevant ITU-T recommendations including: G.703, G.704, G.706, G.711, G.712, G.732, G.784, G.823, G.826, V.28, V.35, V.36, and X.21

Clock Synchronization

Internal clock (50 ppm)

Extracted from E1 port

External via 2,048 MHz clock (ITU-T G.703 § 10) or 64 kHz (G.703 § 1.2.2)

Clock and backup priority rules are selectable via configuration management.

Mechanical Design

Uses same technology as the other products in the Alcatel-Lucent access product family

Plug-in printed boards with Double Euro format. State-of-the-art components ensure low power consumption and high reliability.

Subracks (can be mounted in rack or cabinet):

¬T9 subrack: Width of 120 mm

(4.72 in.), 240 mm (9.45 in.),

360 mm (14.17 in.) or 480 mm

(18.89 in.)

¬19-in. subrack:

-height: 7U (1U = 44.45 mm, 1.75 in.)

-Can be mounted in a 300-mm deep (11.81 in.) ETSI rack

ETSI T9 and 19-in. racks:

¬available in two heights:

2,200 mm (86.61 in.) (with six Alcatel-Lucent 1511 BA subrack mounting levels) and 1,800 mm (70.87 in.) (with five mounting levels)

Cabinets: Both indoor and outdoor variants available

Power Supply

-38.5 V to -72 V DC

110/220 V AC ± 20%

Environment

>Operating temperature: -5 C to +50 C (23 F to 122 F)

>Transport and storage temperature: -40 C to +70 C (-40 F to +158 F)

Compliant with:

¬ETS 300 019-2-1

¬ETS 300 019-2-2

¬ETS 300 019-2-3

EMC

EMC on rack basis (EMC directive 89/336/EEG [EN 50081-1, EN 50082-1])

EMC on subrack basis (ETS 300-386-1)

www.alcatel-lucent.com

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.

© 2008 Alcatel-Lucent. All rights reserved. CAR9718080111 (02)

Page 4
Image 4
Alcatel-Lucent 1511 BA manual Main Characteristics, Clock Synchronization, Mechanical Design, Power Supply, Environment